Part Number 238943

Control Motor

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
238943
Demil:
No
Shelf Life:
UOM:
NIIN:
006352180

Part Information
Mtg holes spotface 0.312in. Diameter irregularly spaced on 2.437 in. Bolt circle

NSN
National Stock Number:
6105-00-635-2180 6105006352180
TXT
Description:
Control Motor
INC
INC
Item Name Code:
19258
MRC:
The distance measured in a straight line from the bottom to the top of an item.AAJT
Overall Height:
2.813 inches
MRC:
A measurement of the longest dimension of an item,in distinction from width.AAJU
Overall Length:
4.031 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.AAJV
Overall Width:
2.375 inches
MRC:
A measurement of the extent of threads,including incomplete threads,along a line parallel to the longitudinal axis.AASA
Thread Length:
0.120 inches first end
MRC:
A measurement of the longest dimension of the tapered portion of an item,in distinction from width.ABND
Taper Length:
0.179 inches first end and 0.189 inches first end
MRC:
None.ABXQ
Flatted Portion Length:
0.3120 inches second end
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac input
MRC:
None.AGRB
Flat Depth:
0.1400 inches second end
MRC:
The means of attaching the item.AXGY
Mounting Method:
Pad
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
8 unthreaded hole
MRC:
The means of cooling used to maintain the required operating temperature of the item.BFMF
Cooling Method:
Nonventilated
MRC:
The current rating of the control field,expressed in amperes.BFMJ
Control Field Current Rating In Amps:
0.335
MRC:
The impedance rating of the control field,expressed in ohms.BFMK
Control Field Impedance Rating In Ohms:
313.0
MRC:
Indicates the type of winding(s) of the control field.BFML
Control Field Winding Type:
Two windings, series connected
MRC:
The means by which the current is rated.BKPB
Current Rating Method:
No load
MRC:
Indicates the torque rating,and its type.BKPH
Torque Rating And Type:
3.0 inch-ounces stalled
MRC:
The government or industrial specification or standard that defines the inclosure feature.BKPQ
Inclosure Specificationification:
Commercial
MRC:
Indicates the type of control field voltage and its rating,expressed in volts.BKPS
Control Field Voltage Type And Rating In Volts:
115.0 ac
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Single phase adaptability and horizontal mounting position and vertical mounting position
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.112 inches first end
MRC:
The amount of taper measured parallel to the longitudinal axis of the item per specific measurement scale.CQRR
Taper:
7.500 per foot in inches first end
MRC:
A measurement of the longest dimension of the shaft projection of an item,in distinction from width.CWCS
Length Of Shaft From Housing:
0.375 inches first end
MRC:
A measurement of the longest dimension of the shaft projection of an item,in distinction from width.CWCS
Length Of Shaft From Housing:
0.531 inches second end
MRC:
The temperature at which the item is designed to operate.CWDY
Tempurature Rating:
65.0 ambient degrees celsius and -55.0 operating degrees celsius and 55.0 operating degrees celsius
MRC:
The speed rating of a rotor,expressed in revolutions per minute.CWFX
Rotor Speed Rating In Rpm:
11400.0 single no load
MRC:
The nominal center to center distance between the mounting facilities parallel to the width.CWFY
Center To Center Distance Between Mounting Facilities Parallel To Width:
2.437 inches
MRC:
The nominal center to center distance between the mounting facilities parallel to the height.CWGD
Center To Center Distance Between Mounting Facilities Parallel To Height:
2.437 inches
MRC:
The amount of current for which an item is rated,expressed in amperes.CWGL
Current Rating In Amps:
0.220 single input
MRC:
Indicates the type of connection,rating sequence,and voltage rating at which the item is designed to operate,expressed in volts.CWGQ
Connection Type And Voltage Rating In Volts:
115.0 line to neutral single input
MRC:
An indication of the characteristic(s) of the shaft end.CWHZ
Shaft End Characteristic:
A2 first style first end and a4 second style first end
MRC:
An indication of the characteristic(s) of the shaft end.CWHZ
Shaft End Characteristic:
A5 single style second end
MRC:
The number of alternating current phases.FAAZ
Phase:
Single input
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
400.0 input
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Unf first end
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
4 screw

Similar Control Motors

« Electrical Motors Catalog
Compare Now »
Clear | Hide