Part Number 2394759

Intravenous Infusion Pu Analyzer

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
2394759
Demil:
Shelf Life:
UOM:
NIIN:
016479673

Part Information
Ida 4 plus three-channel infusion device analyzer

NSN
National Stock Number:
6515-01-647-9673 6515016479673
TXT
Description:
Intravenous Infusion Pu Analyzer
INC
INC
Item Name Code:
47433
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
7.50 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
11.90 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
7.20 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The name and number of those parts furnished with the item of supply that have not been specified elsewhere.AKYN
Furnished Items And Quantity:
Users manual and software (1); 20 ml priming syringe (1); luerlock-3 way (one for each channel); 5-ft plastic drain line (1)
MRC:
The universal medical device nomenclature system code for this item.ALUE
Universal Medical Device Nomenclature System Code:
16720
MRC:
An indication of whether or not the item is portable.APCB
Portability:
Portable
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
90.0 and 260.0
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
The device measures instantaneous flow, average flow, occlusion pressure, and analyzes patient-control analgesia (pca) units; weight, 11 pounds; operating temperature: 59 f to 86 f; storage temperature: 32 f to 104 f; do no leave for more than 48 hours at -4 f; dimensions: 7.5 in l x 7.2 in w x 11. In h; supply voltage: autoswitching 90 vac to 260 vac; supply frequency: 50 hz to 60 hz; supply power: < 30 va; fuse: 20 mm 250 v, 1 a (t) (slow blow); compatible with virtually any type of infusion device; built-in memory to save test results for printing or downloading to computer
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
50.0 or 60.0