Part Number 250F147-5

Flow Switch

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
250f147-5
Demil:
No
Shelf Life:
UOM:
NIIN:
013285444
NSN
National Stock Number:
5930-01-328-5444 5930013285444
TXT
Description:
Flow Switch
INC
INC
Item Name Code:
36841
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
Between 2.620 inches and 2.820 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
1.258 inches
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
Between 2.350 inches and 2.390 inches
MRC:
The temperature at which the item operates.AWTN
Operating Tempurature Rating:
Between 32.0 degrees fahrenheit and 180.0 degrees fahrenheit
MRC:
The means of attaching the item.AXGY
Mounting Method:
Inlet connection
MRC:
An indication of whether the initial action of the contacts occurs as the result of an increase or decrease in stimulus.CQGB
Contact Action Stimulus:
Increase
MRC:
The designation that identifies the electrical configuration of a nonpile-up contact group including the number of switching poles or forms.CRLD
Nonpile-up Contact Arrangement:
1 pole, double throw, one position momentary
MRC:
Indicates the type of terminal for providing electrical connection to the item.CSCF
Terminal Type:
Connector, receptacle
MRC:
The amount of current that the contacts are rated to make or break with a specified load.CTHF
Contact Load Current Rating:
25.0 milliamperes inductive load second voltage
MRC:
The amount of current that the contacts are rated to make or break with a specified load.CTHF
Contact Load Current Rating:
50.0 milliamperes inductive load first voltage
MRC:
The adjustability of the contact.CTYC
Contact Adjustability:
Actuation point not adjustable and deactuation point not adjustable
MRC:
The rating of the stimulus required to actuate and/or deactuate the contact(s).CTYX
Contact Stimulus Rating:
5.60 actuation point gallons per minute and 5.00 deactuation point gallons per minute
MRC:
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.CTZB
Contact Voltage Rating In Volts:
115.0 dc at sea level second voltage
MRC:
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.CTZB
Contact Voltage Rating In Volts:
50.0 dc at sea level first voltage
MRC:
The type of media for which the item is designed.MEDA
Media For Which Designed:
Liquid
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Cylindrical

Similar Flow Switches

« Switches Catalog
Compare Now »
Clear | Hide