Part Number 259814-1

Insulation Breakdown Test Set

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
259814-1
Demil:
No
Shelf Life:
UOM:
NIIN:
006185843
NSN
National Stock Number:
6625-00-618-5843 6625006185843
TXT
Description:
Insulation Breakdown Test Set
INC
INC
Item Name Code:
16408
MRC:
Indicates the type of termination provided on the wire.ABCC
Wire Termination Type:
Clip
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
13.500 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
9.870 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
11.800 inches
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
115.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
60.0 hertz
MRC:
A measurement of the longest dimension of a wire lead.AFSC
Wire Lead Length:
48.000 inches
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Portable
MRC:
Indicates the type of output current whether alternating,direct,or both.ANPN
Output Current Type:
Ac and dc
MRC:
An indication of the type of meter.ANTH
Meter Type:
Voltmeter
MRC:
The number of meters provided.ANTJ
Meter Quantity:
1
MRC:
An indication of the scale range.APSK
Scale Range:
+0.0/+3500.0 volts and +0.0/+2500.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which the output is rated.APTS
Output Frequency Rating:
120.0 hertz
MRC:
The output voltage rating at which the item is designed to operate.AQYB
Output Voltage Rating:
2.500 kilovolts and 3.500 kilovolts
MRC:
The amount of apparent power,as distinguished from true power,for which the item is rated.AQYE
Volt-ampere Rating:
600.0
MRC:
Indicates the type of indicator used to show a leakage condition.AQYK
Leakage Indicator Type:
Lamp
MRC:
The number of test leads provided with the item.AQYL
Test Lead Quantity:
2
MRC:
The number of alternating current phases.FAAZ
Phase:
Single

Similar Insulation Breakdown Test Sets

« Electrical and Electronic Properties Measuring and Testing Instruments Catalog
Compare Now »
Clear | Hide