Part Number
DEMIL
Shelf Life
UOM
NIIN
NSN
National Stock Number:
TXT
Description:
Thermal Relay
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
2.380 inches
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
0.820 inches
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Hermetic
MRC:
The designation that identifies the schematic diagram of the contact configuration.APFR
Contact Arrangement:
Double pole, single throw, normally closed, manual reset
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
1 octal base plug-in
MRC:
The highest voltage at which the contacts are rated for normal operating,expressed in volts.CYCS
Contact Maximum Voltage Rating In Volts:
28.0 dc
MRC:
The highest current at which the contacts are rated for normal operation,expressed in amps.CYCT
Contact Maximum Current Rating In Amps:
3.0 dc
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
8 pin