Part Number 2663277

Stepping Switch

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
2663277
Demil:
No
Shelf Life:
UOM:
NIIN:
004099308

Part Information
Meets criteria of spccintinst 4200.24a

NSN
National Stock Number:
5930-00-409-9308 5930004099308
TXT
Description:
Stepping Switch
INC
INC
Item Name Code:
26954
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
8.375 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
5.563 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
5.875 inches
MRC:
The means of attaching the item.ADJH
Mounting Method:
Flange
MRC:
The means by which the item is controlled.AMWH
Control Method:
Remote
MRC:
The means of restoring the item to a homing position.ANZW
Homing Method:
Through switch contacts
MRC:
The number of bank levels provided.ANZX
Bank Level Quantity:
24
MRC:
The number of contact/s/ /point/ provided in each bank level.ANZY
Contact Quantity Per Bank Level:
26
MRC:
The number of wiper contacts provided in each bank level.ANZZ
Wiper Contact Quantity Per Bank Level:
12
MRC:
Indicates the type of contact/s/ used.APAB
Contact Type:
Bridging and nonbridging
MRC:
The number of bridging levels provided.APAC
Bridging Level Quantity:
1
MRC:
The number of nonbridging levels provided.APAD
Nonbridging Level Quantity:
11
MRC:
The number of magnetic coils provided.APAF
Magnetic Coil Quantity:
1
MRC:
Indicates the type of coil used.APAG
Coil Type:
Drive
MRC:
A measurement of the opposition to the flow of direct or alternating current.APCC
Electrical Resistance:
28.0 ohms
MRC:
The basic form of the auxiliary off-normal contact arrangement.APCD
Auxiliary Off-normal Contact Arrangement:
2c
MRC:
The basic form of the auxiliary interrupter contact arrangement.APCE
Auxiliary Interrupter Contact Arrangement:
1b and 1c
MRC:
An indication of the stepping direction.APCJ
Stepping Direction:
Unidirectional
MRC:
The master requirement codes of those requirements which are technically critical by reason of tolerance,fit,performance,or other characteristics which affect identification of the item.CRTL
Criticality Code Justification:
Feat

Similar Stepping Switches

« Switches Catalog
Compare Now »
Clear | Hide