Part Number 27479

Liquid Level Switch

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
27479
Demil:
No
Shelf Life:
UOM:
NIIN:
009376136
NSN
National Stock Number:
5930-00-937-6136 5930009376136
TXT
Description:
Liquid Level Switch
INC
INC
Item Name Code:
37187
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
48.125 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
6.125 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
6.812 inches
MRC:
The means by which the item is actuated.AFLW
Actuation Method:
Buoyancy
MRC:
An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
Internal Battery Accommodation:
Not included
MRC:
The amount of current at maximum rated voltage for which the item is designed.APGW
Current Rating At Maximum Rated Voltage:
45.0 milliamperes resistive load
MRC:
The amount of voltage for which the item is designed to withstand at the maximum rated current.APGY
Voltage Rating At Maximum Rated Current:
110.0 volts
MRC:
The number of floats provided.AWAE
Float Quantity:
2
MRC:
The temperature at which the item operates.AWTN
Operating Tempurature Rating:
Any acceptable
MRC:
The means of attaching the item.AXGY
Mounting Method:
Flange
MRC:
The installed position for which the item is designed.BBJX
Mounting Position:
Vertical
MRC:
The maximum continuous current which must not be exceeded in order to avoid damage to the item.BJKC
Maximum Current Rating:
90.0 milliamperes resistive load
MRC:
The designation that identifies the schematic diagram of the contact arrangement.BJKD
Contact Arrangement:
2 single pole n.O. As one float control-one for alarm w/2 single pole n.C. Contacts
MRC:
An indication of whether or not a relay is included.BJKG
Relay:
Not included
MRC:
Indicates the type of liquid(s) for which the item is designed.BJKH
Liquid Type For Which Designed:
Various fuels
MRC:
The mounting dimensions of the item.BJKP
Mounting Dimensions:
4-0.562in. Dialholes equally spaced on a 3.12in. Bolt center
MRC:
A measurement of the longest dimension from the mounting surface to the end of the item,which is designed to be inserted into the tank.BJKQ
Tank Insertion Length:
41.500 inches

Similar Liquid Level Switches

« Switches Catalog
Compare Now »
Clear | Hide