Part Number
DEMIL
Shelf Life
UOM
NIIN
NSN
National Stock Number:
TXT
Description:
Fluid Pressure Regulating Valve
MRC:
The basic material of which the body is fabricated.AAFZ
Body Material:
Steel, federal standard 66, aisi 303/sae 30303 or steel, federal standard 66, aisi 304/sae 30304 or steel, federal standard 66, aisi 316/sae 30316
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Straight thru
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Nitrogen, gaseous
MRC:
A narrative description of the type of end connection.ACKM
First End Connection Type:
Unthreaded internal tube
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the end.ACKN
First End Style Designator:
Socket
MRC:
The length of a straight line which passes through the center of the accommodated tube,and terminates at the outside circumference.ACLH
First End Outside Diameter Tube Accommodated:
0.375 inches
MRC:
Indicates whether or not the second end is identical to the first end.ACLR
Second End Relationship With First End:
Identical
MRC:
The part that controls the flow through the item.ADQU
Flow Control Device:
Poppet
MRC:
The element,compound,or mixture of which the flow control device is fabricated.ADQV
Flow Control Device Material:
Nickel copper alloy or steel, corrosion resisting or bronze or stellite or nickel aluminum bronze
MRC:
The number of end connections included in the item.ADQZ
End Connection Quantity:
2
MRC:
Indicates the basic design type used for regulating the item.AEVN
Regulation Type:
Automatic single stage
MRC:
The seat design of the valve stem.AEVQ
Valve Stem Design:
Single seat
MRC:
The means of providing resistance to the media passing through a valve,whereby the valve is actuated to regulate the flow.AEVR
Valve Loading Method:
Spring
MRC:
The maximum pressure of the media on the inlet side at which an item is designed to operate.AEVZ
Maximum Inlet Pressure Rating:
3000.0 pounds per square inch
MRC:
The set /nonadjustable/ pressure of the media on the outlet side.AEWA
Outlet Pressure Setting:
4500.0 pounds per square inch
MRC:
The rated variance of the outlet pressure from the set pressure.AEWB
Outlet Pressure Accuracy Rating:
Not rated
MRC:
An indication of whether or not a filter is included.AEWF
Filter:
Not included
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.AZKQ
Tempurature Rating:
Between -40.0 degrees fahrenheit and 165.0 degrees fahrenheit