Part Number
DEMIL
Shelf Life
UOM
NIIN
NSN
National Stock Number:
TXT
Description:
Saturable Reactor
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
2.062 inches
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.ABKQ
Center To Center Distance Between Mounting Facilities Parallel To Length:
1.500 inches all mounting facilities all center groupings
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.ABKR
Center To Center Distance Between Mounting Facilities Parallel To Width:
1.500 inches all mounting facilities all center groupings
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
2.062 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
2.688 inches
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
415.0 hertz all components
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
4 all groupings
MRC:
The means of attaching the item.AXGY
Mounting Method:
Threaded hole all groupings
MRC:
The purpose and the total number of individual (not electrically connected) windings designed to perform in a transformer.BPLC
Winding Function And Quantity:
12 primary and 1 control all components
MRC:
The number of threads on the item per linear inch measured on a line parallel to the thread axis.CMLP
Thready Qty Per Inch (tpi):
40 all groupings
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.112 inches all groupings
MRC:
The opposition to the flow of direct current offered by an item,expressed in ohms.CRGS
Dc Resistance Rating In Ohms:
400.000 single component 1st control
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
80.00 ac volts single component all primary
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Unc all groupings
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
6 tab, solder lug