Part Number
DEMIL
Shelf Life
UOM
NIIN
NSN
National Stock Number:
TXT
Description:
Fixed Attenuator
MRC:
The primary application for which the item is designed.AAFS
Application Design:
Transmission line
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
2.625 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
0.468 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
1.000 inches
MRC:
A designator indicating a graphic representation,in standard and accepted symbols,of essential electrical-electronic elements and related connections on the item.AEBZ
Schematic Diagram Designator:
Unbalanced "pi"
MRC:
The total opposition (resistive and reactive) which the item offers to the admittance of an entering flow of alternating current,expressed in ohms.AHTY
Input Impedance Rating In Ohms:
50.0
MRC:
The total opposition /resistive and reactive/ which the output of the item provides to match,for maximum transfer of energy,the input impedance of another item,expressed in ohms.AHTZ
Output Impedance Rating In Ohms:
50.0
MRC:
The amount of electrical energy that can be dissipated.AJDB
Power Rating:
500.0 milliwatts average
MRC:
The decrease in the strength of the radio frequency signals,expressed in decibels.AJDK
Rf Signal Attenuation In Decibels:
70.0
MRC:
The limits of permissible variation in the attenuation accuracy from the nominal value at a specified frequency rating or range,expressed in decibels.ASYN
Attenuation Accuracy In Decibels:
-3.00/+3.00
MRC:
The means of attaching the item.AXGY
Mounting Method:
Terminal
MRC:
Indicates the type and number of terminal(s) for providing electrical connection.BBHS
Terminal Type And Quantity:
2 connector
MRC:
The minimum and maximum cyclic changes,per unit of time,for which an item is rated.BNGR
Frequency Range:
Between 30.000 megahertz and 70.000 megahertz