Part Number 301-1

Voltmeter
Description

Connector, coax (rf)

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
301-1
Demil:
Yes - DEMIL/MLI
Shelf Life:
UOM:
NIIN:
000051188
NSN
National Stock Number:
6625-00-005-1188 6625000051188
TXT
Description:
Voltmeter
INC
INC
Item Name Code:
16449
INC
COM
Compliance:
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
Between 5.980 inches and 6.100 inches
MRC:
The length of a straight line which passes through the center of a mounting hole,and terminates at the circumference.ABTB
Mounting Hole Diameter:
Between 0.143 inches and 0.157 inches
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Between 50.000 hertz and 2000.000 kilohertz
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
3.510 inches
MRC:
The length of a straight line which passes through the center of a mounting bolt circle,and terminates at the circumference.AFFL
Mounting Bolt Circle Diameter:
3.160 inches
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Panel
MRC:
The style designation indicating the configuration that most nearly corresponds to the arrangement of the mounting.ANRL
Mounting Arrangement Style:
Three hole/stud bolt circle
MRC:
The minimum and maximum frequencies to which the item will respond without exceeding its accuracy rating.ANSY
Frequency Response Range:
+0.020 to 250.000 kilohertz
MRC:
The hue or tint of the dial scale marking(s).APMM
Dial Scale Marking Color:
Black single indicator single range
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
-2.0 to 2.0 at full scale single indicator all ranges
MRC:
A measurement between the mounting flange and the extremity of the meter, indistinction from height.APST
Meter Depth Behind Mounting Flange:
Between 5.540 inches and 5.660 inches
MRC:
The length of a straight line which passes through the center of the meter body behind the mounting flange, and terminates at the circumference.APSW
Meter Body Diameter Behind Mounting Flange:
Between 2.820 inches and 2.910 inches
MRC:
The hue or tint of the background.AQFY
Background Color:
White single indicator single range
MRC:
The source of power which provides the energy required for the operation of the item.AWZJ
Power Source:
External
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
3 unthreaded hole
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+10.0 volts, ac single indicator single range
MRC:
The means provided for electrical connection to a circuit and the number of each type of connection.CTTD
Circuit Attachment Method And Quantity:
5 solder stud
MRC:
The value(s) of root mean square or direct current potential which must be applied to the item for operation,expressed in volts.CTWN
Operating Voltage Rating In Volts:
Between 105.0 ac and 125.0 ac
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Round flush mtg

Similar Voltmeters

« Electrical and Electronic Properties Measuring and Testing Instruments Catalog
Compare Now »
Clear | Hide