Part Number 30711-063

Laboratory Muffle Furnace

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
30711-063
Demil:
No
Shelf Life:
UOM:
NIIN:
007741208
NSN
National Stock Number:
6640-00-774-1208 6640007741208
TXT
Description:
Laboratory Muffle Furnace
INC
INC
Item Name Code:
48727
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
60.0 hertz
MRC:
An inside measurement taken at right angles to the length of an item,in distinction from thickness.ADJT
Inside Width:
7.550 inches
MRC:
An inside measurement between specified points of an item,in distinction from height.AFEF
Inside Depth:
14.000 inches
MRC:
An inside measurement from the bottom to the top of an item,in distinction from depth.AFMQ
Inside Height:
5.250 inches
MRC:
The name and number of parts supplied with the item which may be required for application.AKYD
Accessory Components And Quantity:
High-temp wire heating elements; thermocouple; 6 foot power cable
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
230.0 volts
MRC:
The amount of electrical energy that can be dissipated.ANPT
Power Rating:
4900.0 watts
MRC:
Indicates the type of control.AQZF
Control Type:
Thermometer-regulator
MRC:
The minimum and maximum operating temperatures at which the item is rated,expressed in degrees celsius.ASQJ
Operating Tempurature Range In Deg Celsius:
+32.0/+1150.0
MRC:
The heat source for which the item is designed.AZZH
Heat Source For Which Designed:
Integral
MRC:
The means by which the item is heated.BDWT
Heating Method:
Electrical
MRC:
An indication of whether or not the item is provided with a water jacket.BGXH
Water Jacket:
Not provided
MRC:
The means used to provide circulation.BHGT
Circulation Method:
Forced air
MRC:
An indication of whether or not an insulated cabinet is provided.BLST
Insulated Cabinet:
Provided
MRC:
The number of alternating current phases.FAAZ
Phase:
Single