Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
30a213-1
Demil:
No
Shelf Life:
UOM:
NIIN:
010464366

Part Information
Drawing name=inertial navigation system ground cooling kit; the kit is contained in a transport case. C/o peri-seals, blower fan assembly, power cord, adapter cord, adapter assembly, duct assembly

NSN
National Stock Number:
5999-01-046-4366 5999010464366
TXT
Description:
Electronic Equipment Air Cooler
INC
INC
Item Name Code:
21166
MRC:
An overall measurement between specified points of an item,in distinction from height.ABFY
Overall Depth:
11.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
13.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
18.000 inches
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
115.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
400.0 hertz
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Aircraft ins systems
MRC:
The relationship of the electrical power source to the item.AKWC
Electrical Power Source Relationship:
Operating
MRC:
An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
Internal Battery Accommodation:
Not included
MRC:
An indication of whether or not a pressurization connection is included.AYZB
Pressurization Connection:
Included
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
Functional Description:
Fins ground cooling kit is designed to supply supplementary cooling air which is required for all ground operations of the inertial measurement uni (imu) . Uses ambient air or adapts to use cooled air
MRC:
Literature and references available for information pertaining to the item.RDAL
Reference Data And Literature:
33da102-13-3