Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
30b02-g129
Demil:
Yes - DEMIL/MLI
Shelf Life:
UOM:
NIIN:
011993894
NSN
National Stock Number:
5895-01-199-3894 5895011993894
TXT
Description:
Pulse Generator
INC
INC
Item Name Code:
00411
INC
COM
Compliance:
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
6.500 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
0.360 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
4.500 inches
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
+0.0/+85.0 degrees celsius
MRC:
The minimum and maximum temperatures at which an item can be stored without detrimental effect.AFJQ
Storage Tempurature Range:
-65.0/+85.0 degrees celsius
MRC:
The style designation indicating the configuration that most nearly corresponds to the basic appearance of the item.AGTA
Basic Shape Style:
Rectangular or square
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encased
MRC:
The means by which the item is operated or controlled.ALBM
Operating Control Method:
Automatic
MRC:
Indicates the type of control.AQZF
Control Type:
Remote
MRC:
Indicates the type of circuit construction provided in the item.BHSX
Circuit Construction Type:
Solid state
MRC:
The time required for one complete pulse per channel.BHTP
Pulse Duration Per Channel:
140.000 microseconds operating channel
MRC:
The length of time it takes the pulse to rise per channel.BHTQ
Pulse Rise Time Per Channel:
0.200 microseconds operating channel
MRC:
The length of time it takes the trailing edge of the pulse to fall per channel.BHTR
Pulse Decay Time Per Channel:
1.000 microseconds operating channel
MRC:
The maximum absolute peak value of the pulse per channel.BHTW
Pulse Peak Amplitude Per Channel:
1.400 volts operating channel
MRC:
The value(s) of the potential supplied from an exterior direct current source to operate the item,expressed in volts.BKFB
External Dc Operating Voltage In Volts:
15.0 single voltage