Part Number 30T117HAT50HZ50CAMB

Power Autotransforme Transformer

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
30t117hat50hz50camb
Demil:
No
Shelf Life:
UOM:
NIIN:
014164381
NSN
National Stock Number:
5950-01-416-4381 5950014164381
TXT
Description:
Power Autotransforme Transformer
INC
INC
Item Name Code:
36166
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
24.500 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
31.500 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
16.500 inches
MRC:
The relationship of the phase input to the phase output of an alternating current.ACZC
Input-output Phase Relationship:
Three phase to three phase single component
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
The purpose and the total number of individual (not electrically connected) windings designed to perform in a transformer.BPLC
Winding Function And Quantity:
1 primary, fixed autotransformer type single component
MRC:
The maximum power for which the winding of the item is rated.CRMJ
Winding Power Rating:
30.0 kilovolt-amperes single component single primary input
MRC:
The maximum power for which the winding of the item is rated.CRMJ
Winding Power Rating:
30.0 kilovolt-amperes single component single primary output
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
120.00 ac volts single component single primary output or 208.00 ac volts single component single primary output
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
220.00 ac volts single component single primary input or 380.00 ac volts single component single primary input
MRC:
The document designator of the specification or standard which established the item of supply.ZZZK
Specification Data:
65597-043376 manufacturers specification control

Similar Power Autotransforme Transformers

« Coils and Transformers Catalog
Compare Now »
Clear | Hide