Part Number
DEMIL
Shelf Life
UOM
NIIN
NSN
National Stock Number:
TXT
Description:
Line Electro-mechanical Actuator
MRC:
Indicates the type of terminals for providing electrical connection to the item.AARB
Terminal Type:
Connector
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Dc
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
Between 11.830 inches and 17.040 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
4.760 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
4.970 inches
MRC:
The maximum altitude at which the item is rated to function.AKAE
Maximum Operating Altitude Rating:
50000.0 feet
MRC:
The working period under which the item was designed to operate.AKPS
Duty Cycle:
Intermittent
MRC:
The electrical current rating,expressed in amperes.AMPS
Current Rating In Amps:
5.0
MRC:
A measurement of the longest dimension of the stroke,in distinction from width.AMWL
Stroke Length:
4.160 inches
MRC:
An indication of whether or not a limit switch control is included.AWQN
Limit Switch Control:
Included
MRC:
The means used to reset the thermal protector.AWQP
Thermal Protector Reset Method:
Automatic
MRC:
An indication of whether or not a manual override is included.AWQR
Manual Override:
Not included
MRC:
The tension stress applied to the item under load conditions.AWTA
Tension Load Rating:
800.0 pounds operating err-100
MRC:
The tension stress applied to the item under load conditions.AWTA
Tension Load Rating:
1200.0 pounds static err-100
MRC:
The compression stress applied to the item under load conditions.AWTC
Compression Load Rating:
400.0 pascal grams operating
MRC:
The compression stress applied to the item under load conditions.AWTC
Compression Load Rating:
600.0 pascal grams static
MRC:
The rate of linear travel per unit of time.AWTE
Rated Stroke Velocity:
0.231 inches per second
MRC:
The maximum operating on time and the minimum off time for a complete cycle of an item.AYEK
Intermittent Operation Duty Cycle:
3.0 minutes on and 17.0 minutes off
MRC:
The facility for mounting the item.AZGM
Mounting Facility:
Unthreaded mounting holes
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
24.0