Part Number 32005-026

Tachometer Generator
Description

Tachometer generator

Stock Availability  condition code chart

Part number 32005-026 is in stock in the following quantities and conditions.

  • AR: 16
  • OH: 1
  • NS: 1
  • SV: 1

Note: Availability of this item was last updated 12/05/2022 and may have changed since then. Request a quote for up to date pricing and availability.

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
32005-026
Demil:
No
Shelf Life:
UOM:
NIIN:
001792175
NSN
National Stock Number:
6680-00-179-2175 6680001792175
TXT
Description:
Tachometer Generator
INC
INC
Item Name Code:
20241
MRC:
The distance measured in a straight line from the bottom to the top of an item.AAJT
Overall Height:
2.438 inches
MRC:
A measurement of the longest dimension of an item,in distinction from width.AAJU
Overall Length:
4.034 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.AAJV
Overall Width:
2.438 inches
MRC:
None.ABXQ
Flatted Portion Length:
0.400 inches single end and 0.534 inches single end
MRC:
The direction of rotation of a rotating shaft as viewed from the drive end.AKCT
Shaft Rotation Direction:
Clockwise single end
MRC:
The shortest straight line between flats,perpendicular to the height.ASDB
Width Across Flats:
0.243 inches single end and 0.245 inches single end
MRC:
The means of attaching the item.AXGY
Mounting Method:
Pad
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
4 unthreaded hole
MRC:
The speed at which the calibration is determined,expressed in revolutions per minute.BFLQ
Calibration Speed In Rpm:
4200.0
MRC:
An indication of the type of calibration voltage output,expressed in volts.BKPC
Calibration Voltage Output Type In Volts:
21.0 ac
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Horizontal mounting position and vertical mounting position
MRC:
A measurement of the longest dimension of the shaft projection of an item,in distinction from width.CWCS
Length Of Shaft From Housing:
0.467 inches single end
MRC:
The nominal center to center distance between the mounting facilities parallel to the width.CWFY
Center To Center Distance Between Mounting Facilities Parallel To Width:
1.876 inches
MRC:
The nominal center to center distance between the mounting facilities parallel to the height.CWGD
Center To Center Distance Between Mounting Facilities Parallel To Height:
1.876 inches
MRC:
An indication of the characteristic(s) of the shaft end.CWHZ
Shaft End Characteristic:
A15 single style single end
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
81349-mil-g-26611a specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.).
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
1 receptacle

Similar Tachometer Generators

« Liquid and Gas Flow, Liquid Level and Mechanical Motion Measuring Instruments Catalog
Compare Now »
Clear | Hide