Part Number 322A514-4-0

S Electrical Insulation Sleeving

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
322a514-4-0
Demil:
No
Shelf Life:
UOM:
NIIN:
010842597

Part Information
Main body id 0.700 in. Min as supplied, 0.350 in. Maximum after unretricted recovery opposite end; wall thk rapers to 0.050 in. as supplied

NSN
National Stock Number:
5970-01-084-2597 5970010842597
TXT
Description:
S Electrical Insulation Sleeving
INC
INC
Item Name Code:
61626
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.ABJH
Tempurature Rating:
-55.0 degrees celsius
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Corrosion resistant and flame resistant and mildew resistant and solvent resistant and water resistant
MRC:
None.AFZT
Distance From Centerline Of Main Body To End Of First Branch:
1.350 inches after unrestricted recovery and 1.650 inches after unrestricted recovery
MRC:
None.AFZT
Distance From Centerline Of Main Body To End Of First Branch:
Any acceptable as supplied
MRC:
None.AFZU
Main Body Inside Diameter:
0.600 inches after unrestricted recovery
MRC:
None.AFZU
Main Body Inside Diameter:
1.200 inches as supplied
MRC:
None.AFZV
First Branch Inside Diameter:
0.350 inches after unrestricted recovery
MRC:
None.AFZV
First Branch Inside Diameter:
0.700 inches as supplied
MRC:
None.AGAB
Main Body Wall Thickness:
0.090 inches after unrestricted recovery
MRC:
None.AGAB
Main Body Wall Thickness:
0.090 inches as supplied
MRC:
None.AGAC
First Branch Wall Thickness:
0.040 inches after unrestricted recovery and 0.060 inches after unrestricted recovery
MRC:
None.AGAC
First Branch Wall Thickness:
0.050 inches as supplied
MRC:
None.AGAH
Main Bodylength:
3.200 inches after unrestricted recovery
MRC:
None.AGAH
Main Bodylength:
3.170 inches as supplied
MRC:
None.AGAQ
Angle Between Main Body And First Branch Centerlines In Deg:
85.0 after unrestricted recovery and 95.0 after unrestricted recovery
MRC:
None.AGAQ
Angle Between Main Body And First Branch Centerlines In Deg:
5.0 as supplied and 25.0 as supplied
MRC:
The maximum rated load in tension applied in a longitudinal direction,per unit of cross-sectional area,that the material can withstand without rupture.CQBC
Min. Tensile Strength (psi):
1200 pounds per square inch
MRC:
Flexible,capable of being bent,turned or twisted,within limits,without breaking,or rigid,resisting change of form,inflexible.FLEX
Flexibility:
Flexible
MRC:
A characteristic of light that can be specified in terms of luminance,dominant wavelength,and purity.HUES
Color:
Any acceptable
MRC:
The element,compound,or mixture of which an item is fabricated,excluding any surface treatment.MATL
Material:
Plastic, polyolefin, rt-1304, raychem corp
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Plastic, polyolefin, rt-1304, raychem corp
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Transition-t
MRC:
The maximum potential gradient the insulating material can withstand,per unit thickness,without rupture.UKBG
Dielectric Material Voltage Rating Per Unit Thickness:
200.0 volts per military /0.001 inch/

Similar S Electrical Insulation Sleevings

« Electrical Insulators and Insulating Materials Catalog
Compare Now »
Clear | Hide