Part Number 335C790H43

Meter Movement Relay

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
335c790h43
Demil:
No
Shelf Life:
UOM:
NIIN:
006193550
NSN
National Stock Number:
5945-00-619-3550 5945006193550
TXT
Description:
Meter Movement Relay
INC
INC
Item Name Code:
03884
MRC:
The number of terminals for providing electrical connection to the item.AARA
Terminal Quantity:
2
MRC:
Indicates the type of terminals for providing electrical connection to the item.AARB
Terminal Type:
Tab, solder lug
MRC:
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
Case Material:
Metal
MRC:
The pattern or arrangement that describes the mounting configuration of the item.ALGC
Mounting Configuration:
Three 0.125 in. Diameter mtg holes equally spaced on a 1.220 in. @radius, 120 degrees apart
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
125.0 volts
MRC:
The number and combination/s/ of the basic contact forms,in the order of assemblage,which make up the switching structure of the main contact/s/.APDY
Main Contact Form Arrangement:
1pdt
MRC:
Indicates the type of current used by the main contact/s/.APEB
Main Contact Current Type:
Dc
MRC:
The current rating of the main contact/s/.APEC
Main Contact Current Rating:
20.0 amperes
MRC:
Indicates the type of current used in the meter movement.APGN
Meter Movement Current Type:
Dc
MRC:
The amount of voltage required to operate the meter movement,expressed in volts.APGP
Meter Movement Voltage In Volts:
50.000
MRC:
An indication of the minimum and maximum amount of current used in the meter movement.APGR
Meter Movement Current Range:
+0.0/+20.0 amperes
MRC:
An indication of the direction of the meter movement reading range.APGT
Meter Movement Range Direction:
Top to bottom
MRC:
The cycles per second /hertz/ of current of the meter movement.APML
Meter Movement Frequency Rating:
60.0 hertz
MRC:
Indicates the type of mount utilized to support the meter.APMR
Meter Mounting Type:
Surface
MRC:
An indication of whether or not the reset facilities are provided.APNR
Reset Facility Feature:
Not provided

Similar Meter Movement Relaies

« Relays and Solenoids Catalog
Compare Now »
Clear | Hide