Part Number 3467-2003

Electrical Power Cable
Stock Availability  condition code chart

Part number 3467-2003 is in stock in the following quantities and conditions.

  • NE: 339

Note: Availability of this item was last updated 01/31/2024 and may have changed since then. Request a quote for up to date pricing and availability.

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
3467-2003
Demil:
No
Shelf Life:
UOM:
NIIN:
012248313

Part Information
Kpolyester tapes under outer shield braid and outer jacket are optional and sixth grouping arrangement eleventh and twelfth conductor through twelfth grouping arrangement twenty-third and twenty-fourth conductor

NSN
National Stock Number:
6145-01-224-8313 6145012248313
TXT
Description:
Electrical Power Cable
INC
INC
Item Name Code:
00232
MRC:
The style designation indicating the configuration that most nearly corresponds to the cross-sectional shape of the item.AAGR
Cross Sectional Shape:
Round
MRC:
The length of a straight line which passes through the center of a cross section,and terminates at the outside circumference.ADVL
Cross Section Outside Diameter:
0.833 inches
MRC:
The number of electrical conductors included on the item.AMQN
Conductor Quantity:
24
MRC:
The number of strands per conductor.BLNZ
Strand Quantity Per Conductor:
7 all conductors
MRC:
The fabricated form of the conductor.CXCW
Conductor Form:
Stranded all conductors
MRC:
The designation used to describe the round stranded or round solid conductor size.CXDC
Round Conductor Size:
18 awg all conductors
MRC:
The american wire gage size of the individual strands of wire used in each stranded conductor.CXDG
Strand Awg Size Per Conductor:
26 all conductors
MRC:
The arrangement and number of arrangements of the conductors.CXDQ
Conductor Arrangement And Quantity:
12 twisted pair
MRC:
The identification of the conductors within a group.CXFG
Conductor Sequence Within Groups:
Fifth conductor third group and sixth conductor third group
MRC:
The identification of the conductors within a group.CXFG
Conductor Sequence Within Groups:
First conductor first group and second conductor first group
MRC:
The identification of the conductors within a group.CXFG
Conductor Sequence Within Groups:
Ninth conductor fifth group and tenth conductor fifth group
MRC:
The identification of the conductors within a group.CXFG
Conductor Sequence Within Groups:
Seventh conductor fourth group and eighth conductor fourth group
MRC:
The identification of the conductors within a group.CXFG
Conductor Sequence Within Groups:
Third conductor second group and fourth conductor second group
MRC:
The maximum sustained voltage that can be safely applied to the item without risking failure or damage.CXFK
Voltage Rating:
600.0 root mean square (rms) operating voltage all conductors
MRC:
A characteristic of light that can be specified in terms of luminance,dominant wavelength,and purity.HUES
Color:
Black 1st position jacket cable
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper core conductor all conductors
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Plastic polyvinylidene fluoride 2nd position jacket all conductors
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Plastic polyalkene 1st position primary insulation all conductors
MRC:
The specification,standard,or manufacturers reference,and the classification designation,such as class,condition,temper,and the like,that identifies the material.MDCL
Material Specification:
Astm b3 assn standard single material response core conductor all conductors

Similar Electrical Power Cables

« Wire and Cable, Electrical Catalog
Compare Now »
Clear | Hide