Part Number
DEMIL
Shelf Life
UOM
NIIN
Part Information
Kpolyester tapes under outer shield braid and outer jacket are optional and sixth grouping arrangement eleventh and twelfth conductor through twelfth grouping arrangement twenty-third and twenty-fourth conductor
NSN
National Stock Number:
TXT
Description:
Electrical Power Cable
MRC:
The style designation indicating the configuration that most nearly corresponds to the cross-sectional shape of the item.AAGR
Cross Sectional Shape:
Round
MRC:
The length of a straight line which passes through the center of a cross section,and terminates at the outside circumference.ADVL
Cross Section Outside Diameter:
0.833 inches
MRC:
The number of electrical conductors included on the item.AMQN
Conductor Quantity:
24
MRC:
The number of strands per conductor.BLNZ
Strand Quantity Per Conductor:
7 all conductors
MRC:
The fabricated form of the conductor.CXCW
Conductor Form:
Stranded all conductors
MRC:
The designation used to describe the round stranded or round solid conductor size.CXDC
Round Conductor Size:
18 awg all conductors
MRC:
The american wire gage size of the individual strands of wire used in each stranded conductor.CXDG
Strand Awg Size Per Conductor:
26 all conductors
MRC:
The arrangement and number of arrangements of the conductors.CXDQ
Conductor Arrangement And Quantity:
12 twisted pair
MRC:
The identification of the conductors within a group.CXFG
Conductor Sequence Within Groups:
Fifth conductor third group and sixth conductor third group
MRC:
The identification of the conductors within a group.CXFG
Conductor Sequence Within Groups:
First conductor first group and second conductor first group
MRC:
The identification of the conductors within a group.CXFG
Conductor Sequence Within Groups:
Ninth conductor fifth group and tenth conductor fifth group
MRC:
The identification of the conductors within a group.CXFG
Conductor Sequence Within Groups:
Seventh conductor fourth group and eighth conductor fourth group
MRC:
The identification of the conductors within a group.CXFG
Conductor Sequence Within Groups:
Third conductor second group and fourth conductor second group
MRC:
The maximum sustained voltage that can be safely applied to the item without risking failure or damage.CXFK
Voltage Rating:
600.0 root mean square (rms) operating voltage all conductors
MRC:
A characteristic of light that can be specified in terms of luminance,dominant wavelength,and purity.HUES
Color:
Black 1st position jacket cable
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper core conductor all conductors
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Plastic polyvinylidene fluoride 2nd position jacket all conductors
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Plastic polyalkene 1st position primary insulation all conductors
MRC:
The specification,standard,or manufacturers reference,and the classification designation,such as class,condition,temper,and the like,that identifies the material.MDCL
Material Specification:
Astm b3 assn standard single material response core conductor all conductors