Part Number 346BADD3

Frequency Calibrator

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
346badd3
Demil:
No
Shelf Life:
UOM:
NIIN:
014791643

Part Information
Mfg name is synthesized calibrator. The pmel's using the 346b, (6625-01-424-2124) these calibrators are being upgraded. This upgrade adds a differential picocoulomb output to the calibrator, with this upgrade (add3) you can store 24 distinct setups each having 31 settings of frequency, amplitude and dwell time

NSN
National Stock Number:
6625-01-479-1643 6625014791643
TXT
Description:
Frequency Calibrator
INC
INC
Item Name Code:
00860
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
19.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
3.500 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
13.000 inches
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
115.0 volts and 230.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Between 50.0 hertz and 400.0 hertz
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
This synthesized calibrato (346b add3) is part of the a/m99t-2, calibration trailer
MRC:
An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
Internal Battery Accommodation:
Not included
MRC:
The specific frequency(ies) for each individual transmission path.ANLE
Individual Channel Frequency:
Between 0.1 kilohertz and 99.0 kilohertz
MRC:
The number of individual channels provided.BGLD
Individual Channel Quantity:
2
MRC:
An indication of the accuracy of the frequency,expressed in percent.BGLF
Frequency Accuracy In Percent:
+0.005/+0.010
MRC:
An indication of whether or not an internal calibration crystal(s) is included.BJLM
Internal Calibration Crystal:
Included
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
Functional Description:
The a/m99t-2 calibration trailer is used to calibrate the vibration monitor/analyzers that are used in the a/m37t2 jet engine test stand

Similar Frequency Calibrators

« Electrical and Electronic Properties Measuring and Testing Instruments Catalog
Compare Now »