Part Number
DEMIL
Shelf Life
UOM
NIIN
NSN
National Stock Number:
TXT
Description:
Rota Electro-mechanical Actuator
MRC:
Indicates the type of terminals for providing electrical connection to the item.AARB
Terminal Type:
Connector
MRC:
The length of a straight line which passes through the center of the body,and terminates at the circumference.ABPM
Body Diameter:
Between 2.683 inches and 2.688 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Dc
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
3.390 inches
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Any acceptable
MRC:
The speed of the drive shaft required to produce the rated capacity of an item,expressed in revolutions per minute.AEQC
Operating Speed At Rated Capacity In Rpm:
210.0
MRC:
The maximum altitude at which the item is rated to function.AKAE
Maximum Operating Altitude Rating:
50000.0 feet
MRC:
The direction of rotation of a rotating shaft as viewed from the drive end.AKCT
Shaft Rotation Direction:
Clockwise and counterclockwise
MRC:
Indicates the type of drive for turning,rotating,or positioning the mechanism.AKCV
Drive Type:
Direct
MRC:
The working period under which the item was designed to operate.AKPS
Duty Cycle:
Intermittent
MRC:
The electrical current rating,expressed in amperes.AMPS
Current Rating In Amps:
2.5
MRC:
The means by which the braking action is applied.ATWS
Braking Method:
Electric
MRC:
Indicates the type of clutch provided.ATXA
Clutch Type:
Electromagnetic
MRC:
The rated torque of the output drive.AWQM
Output Drive Torque Rating:
3.0 inch-pounds
MRC:
An indication of whether or not a limit switch control is included.AWQN
Limit Switch Control:
Not included
MRC:
An indication of whether or not a manual override is included.AWQR
Manual Override:
Not included
MRC:
An indication of the rotation of the angular shaft.AWTZ
Angular Shaft Rotation:
Unlimited
MRC:
The maximum operating on time and the minimum off time for a complete cycle of an item.AYEK
Intermittent Operation Duty Cycle:
3.0 minutes on and 12.0 minutes off
MRC:
The facility for mounting the item.AZGM
Mounting Facility:
Mounting brackets
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
26.0