Part Number 400-4970

Signal Generator

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
400-4970
Demil:
No
Shelf Life:
UOM:
NIIN:
011350002
NSN
National Stock Number:
6625-01-135-0002 6625011350002
TXT
Description:
Signal Generator
INC
INC
Item Name Code:
03901
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
18.600 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
5.700 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
18.000 inches
MRC:
The range of complete cyclic changes,per unit of time,for which an item is rated.AFGQ
Frequency Range Rating:
+5.400/+12.500 gigahertz
MRC:
An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
Internal Battery Accommodation:
Not included
MRC:
The total opposition (resistive and reactive) presented by the item to an alternating current load.AMNE
Output Impedance Rating:
50.0 ohms
MRC:
The number of specified ranges of frequencies or wavelengths operating between two stated limits.ANLC
Frequency Band Quantity:
1
MRC:
Indicates the type of modulation provided.AYYE
Modulation Type:
Am and fm and pulse
MRC:
The degree of conformity of a measurement to a standard or true value for which the calibration is rated.BDHW
Calibration Accuracy Rating:
Porm1.000 pct
MRC:
An indication of whether or not a crystal controlled feature is provided.BHFY
Crystal Controlled Feature:
Not provided
MRC:
An indication of the maximum signal output transmitted by the item.BHGB
Maximum Signal Output:
Plus10.0 db to minus 130.0 db leveled into 50.0 ohms
MRC:
Indicates the location of the modulator on the item.BHGD
Modulator Location:
Any acceptable
MRC:
The number of complete cyclic changes,per unit of time,for which the modulation is rated.BHQD
Modulated Frequency Rating:
Between 0.0 megahertz and 10.0 megahertz
MRC:
The number of complete cyclic changes,per unit of time,for which the pulse repetition is rated.BHQF
Pulse Repetition Frequency Rating:
Between 0.0 megahertz and 1.0 megahertz