Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
4001-086-205
Demil:
No
Shelf Life:
UOM:
NIIN:
015340073

Part Information
Sealed circuit breaker

NSN
National Stock Number:
5925-01-534-0073 5925015340073
TXT
Description:
Circuit Breaker
INC
INC
Item Name Code:
00136
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Single pole type
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
2.189 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
0.750 inches
MRC:
The center to center distance between terminals parallel to the length of the item.AEBP
Center To Center Distance Between Terminals Parallel To Length:
0.703 inches
MRC:
The distance between centerlines of mounting facilities parallel to the length of the item.AEBY
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
Between 1.802 inches and 1.822 inches
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
B-52 aircraft
MRC:
None.AJEC
Boss Height:
0.374 inches
MRC:
None.AJWX
Mounting Surface To Terminal End Distance:
1.852 inches
MRC:
The number of poles included in the item.AKPX
Pole Quantity:
1
MRC:
The maximum current load that each pole is rated to carry continuously.CPLM
Maximum Continuous Load Current Rating Per Pole:
2.5 amperes ac single location and 2.5 amperes dc single location
MRC:
The means provided to reposition the mechanism so that the device is ready to function.CPRQ
Reset Method:
Manual
MRC:
Indicates the type of mechanism provided for tripping main contacts.CPRR
Main Contact Tripping Mechanism Type:
Trip free
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
2 screw