Part Number
DEMIL
Shelf Life
UOM
NIIN
NSN
National Stock Number:
TXT
Description:
Solenoid Valve
MRC:
The part that controls the flow through the item.ADQU
Flow Control Device:
Disk
MRC:
The position of the moving member/s/ controlling flow through the valve with the solenoid in the de-energized position.ADSK
Flow Control Device Normal Operation Position:
Closed
MRC:
The number of bolt holes provided on the item.AECS
Bolt Hole Quantity:
3 2nd end
MRC:
A nominal measurement taken at right angles to the length of an item,in distinction from thickness.AKGF
Width:
1.750 inches 1st end
MRC:
A nominal measurement of the longest dimension of an item,in distinction from width.AKGG
Length:
1.750 inches 1st end
MRC:
The means used to control the operation of the valve.AQLR
Valve Operation Method:
Solenoid
MRC:
The physical configuration of the flange.ARKN
Flange Shape:
Triangular with holes 2nd end
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
Flange 2nd end
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
Flange 1st end
MRC:
The difference,at the rated temperature,between the inlet and outlet pressure for positive operation.CQCP
Inlet/outlet Operating Pressure Differential:
182.0 pounds per square inch
MRC:
The maximum pressure at which the item is rated for operation.CQGM
Maximum Operating Pressure:
200.0 pounds per square inch single response
MRC:
The total electrical voltage,expressed in volts,and the type of current whether alternating or direct.CSBH
Voltage In Volts And Current Type:
24.0 dc
MRC:
The face to face distance.CWCF
Face To Face Distance:
2.891 inches
MRC:
The nominal length of a straight line which passes through the center of the bolt hole,and terminates at the circumference.CWCQ
Bolt Hole Diameter:
0.218 inches 2nd end
MRC:
The nominal length of a straight line which passes through the center of the bolt circle,and terminates at the circumference.CWCT
Bolt Circle Diameter:
1.400 inches 2nd end
MRC:
The design of the flange face.CWDF
Flange Face Design:
Plain 1st end
MRC:
The design of the flange face.CWDF
Flange Face Design:
Plain 2nd end
MRC:
The type of media for which the item is designed.MEDA
Media For Which Designed:
Air single response
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Err-090
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Straight through flanged ends