Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
410c
Demil:
Yes - DEMIL/MLI
Shelf Life:
UOM:
NIIN:
009694105

Part Information
Ranges for vac, 7 ranges-.5, 1.5, 5 sequence; vdc ranges 11 ranges-15, 50 sequence; dc amps, 11 ranges 1.5, 5 sequence; ohms-7 ranges; includes db display reference

NSN
National Stock Number:
6625-00-969-4105 6625009694105
TXT
Description:
Multimeter
INC
INC
Item Name Code:
00794
INC
COM
Compliance:
MRC:
The type of electrical circuit in which the item is designed to be used.AACT
Circuit Current For Which Designed:
Ac
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
11.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
6.500 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
5.125 inches
MRC:
The number of scale divisions.ABWG
Scale Division Quantity:
50 single indicator 1st range
MRC:
The number of scale divisions.ABWG
Scale Division Quantity:
50 single indicator 3rd range
MRC:
The number of scale divisions.ABWG
Scale Division Quantity:
50 single indicator 2nd range
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Between 50.000 hertz and 1.000 kilohertz
MRC:
Indicates the type of device used to register the condition(s).AMKD
Indicator Type:
Dial w/pointer
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Bench
MRC:
The rated sensitivity of the item.ANTG
Sensitivity Rating:
1.0 milliamperes
MRC:
The hue or tint of the dial scale marking(s).APMM
Dial Scale Marking Color:
Black single indicator all ranges
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
-2.0/+2.0 at 1/2 scale single indicator 4th range
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
-2.0/+2.0 at full scale single indicator 2nd range
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
-3.0/+3.0 at full scale single indicator 1st range
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
-3.0/+3.0 at full scale single indicator 3rd range
MRC:
The hue or tint of the pointer.ASSS
Pointer Color:
Black single indicator all ranges
MRC:
Indicates the type of graduations provided on the scale.BHDC
Scale Graduation Type:
Linear single indicator 1st range
MRC:
Indicates the type of graduations provided on the scale.BHDC
Scale Graduation Type:
Linear single indicator 2nd range
MRC:
Indicates the type of graduations provided on the scale.BHDC
Scale Graduation Type:
Linear single indicator 3rd range
MRC:
Indicates the type of graduations provided on the scale.BHDC
Scale Graduation Type:
Nonlinear single indicator 4th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+10.0 megohms single indicator 4th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+300.0 volts, ac single indicator 1st range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
-150.0/+150.0 milliamps single indicator 3rd range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
-1500.0/+1500.0 volts, dc single indicator 2nd range
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Autoranging
MRC:
The deviation from a standard or true value for which the item is rated.CTPT
Accuracy Rating:
Pct of range plus pct of reading single indicator all ranges
MRC:
The means provided for electrical connection to a circuit and the number of each type of connection.CTTD
Circuit Attachment Method And Quantity:
3 clip and 1 probe, direct contact
MRC:
The value(s) of root mean square or direct current potential which must be applied to the item for operation,expressed in volts.CTWN
Operating Voltage Rating In Volts:
Between 115.0 ac and 230.0 ac
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
Literature and references available for information pertaining to the item.RDAL
Reference Data And Literature:
To 33a1-12-704-11
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Enamel
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
D1 rectangular or square

Similar Multimeters

« Electrical and Electronic Properties Measuring and Testing Instruments Catalog
Compare Now »
Clear | Hide