Part Number 41

Insulation Breakdown Test Set

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
41
Demil:
No
Shelf Life:
UOM:
NIIN:
003917956
NSN
National Stock Number:
6625-00-391-7956 6625003917956
TXT
Description:
Insulation Breakdown Test Set
INC
INC
Item Name Code:
16408
MRC:
Indicates the type of termination provided on the wire.ABCC
Wire Termination Type:
Clip
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
18.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
9.500 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
11.500 inches
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
110.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
60.000 hertz
MRC:
A measurement of the longest dimension of a wire lead.AFSC
Wire Lead Length:
72.000 inches
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Portable
MRC:
Indicates the type of output current whether alternating,direct,or both.ANPN
Output Current Type:
Dc
MRC:
An indication of the type of meter.ANTH
Meter Type:
Ammeter and voltmeter
MRC:
The number of meters provided.ANTJ
Meter Quantity:
1
MRC:
An indication of the scale range.APSK
Scale Range:
+0.0/+100.0 microamps and +0.0/+15.0 kilovolts
MRC:
The output voltage rating at which the item is designed to operate.AQYB
Output Voltage Rating:
Between 2.000 kilovolts and 15.000 kilovolts
MRC:
Indicates the type of indicator used to show a leakage condition.AQYK
Leakage Indicator Type:
Lamp
MRC:
The number of test leads provided with the item.AQYL
Test Lead Quantity:
2
MRC:
The device provided to protect the circuit from an electrical overload condition.AQYM
Circuit Overload Protection Device:
Fuse
MRC:
The number of alternating current phases.FAAZ
Phase:
Single

Similar Insulation Breakdown Test Sets

« Electrical and Electronic Properties Measuring and Testing Instruments Catalog
  • T4
    NSN: 6625-00-391-7957
  • TI42407
    NSN: 6625-00-391-8894
  • MV77B1
    NSN: 6625-00-392-0518
  • 5245
    NSN: 6625-00-392-0582
  • 2732
    NSN: 6625-00-392-2602
Compare Now »
Clear | Hide