Part Number
DEMIL
Shelf Life
UOM
NIIN
Part Information
Three filtered functions
NSN
National Stock Number:
TXT
Description:
Band Pass Filter
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
0.928 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
1.885 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
1.445 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
0.796 inches
MRC:
The distance between centerlines of mounting facilities parallel to the width of the item.AEHA
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
1.250 inches
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-55.0/+85.0 degrees celsius
MRC:
The frequency at which the insertion loss is measured per function,and to which all related attenuation loss measurements are referred.AHAJ
Reference Frequency Per Function:
850.0 single high pass pulses per second850.0 single high pass two phase to two phase850.0 single high pass two phase to three phase
MRC:
The total opposition per function,presented by a source of energy to the input terminals of an item.AHAQ
Source Impedance Rating Per Function:
50.0 ohms 1st band pass50.0 ohms 2nd band pass50.0 ohms 3rd band pass
MRC:
The total opposition per function,presented by a load to the output terminals of an item.AHAS
Load Impedance Per Function:
50.0 ohms 1st band pass50.0 ohms 2nd band pass50.0 ohms 3rd band pass
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Hermetically sealed
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
5 terminal
MRC:
The ratio per function of the power delivered to the load before insertion of the filter to the power delivered to the load after insertion of the filter,expressed in decibels.CQDR
Insertion Loss At Reference Frequency Per Function In Decibels:
3.0 1st band pass3.0 2nd band pass3.0 3rd band pass
MRC:
Indicates the functional type and number of terminals providing electrical connection to the item.CQDW
Functional Terminal Type And Quantity:
2 pin input 1st function3 pin output 2nd function
MRC:
The specified frequencies,per function,at which losses in signal strength are,by design or measurement,established in a filter circuit.CQFC
Specified Frequencies Of Discrimination Per Function:
750.00 hertz 1st band pass 1st function and 800.00 hertz 1st band pass 1st function and 900.00 hertz 1st band pass 1st function and 950.00 hertz 1st band pass 1st function750.00 hertz 2nd band pass 2nd function and 800.00 hertz 2nd band pass 2nd function and 900.00 hertz 2nd band pass 2nd function and 950.00 hertz 2nd band pass 2nd function750.00 hertz 3rd band pass 3rd function and 800.00 hertz 3rd band pass 3rd function and 900.00 hertz 3rd band pass 3rd function and 950.00 hertz 3rd band pass 3rd function
MRC:
The chemical compound or mechanical mixture properties of which the body is fabricated.CQRG
Body Material:
Metal
MRC:
The difference,per function,between the limiting frequencies within which performance,in respect to some characteristic,falls within specified limits.CRBB
Frequency Band Width Per Function:
800.00 hertz 1st band pass and 900.00 hertz 1st band pass800.00 hertz 2nd band pass and 900.00 hertz 2nd band pass800.00 hertz 3rd band pass and 900.00 hertz 3rd band pass
MRC:
The algebraic difference between the insertion loss at a specified frequency and the insertion loss at the reference frequency per function,expressed in decibels.CRBC
Discrimination At Specificationified Frequencies Per Function In Decibels:
3.0 1st band pass 1st function and 60.0 1st band pass 1st function3.0 2nd band pass 2nd function and 60.0 2nd band pass 2nd function3.0 3rd band pass 3rd function and 60.0 3rd band pass 3rd function
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Rectangular terminal/terminals on one surface