Part Number
DEMIL
Shelf Life
UOM
NIIN
NSN
National Stock Number:
TXT
Description:
Power Transformer
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
5.312 inches
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.ABKQ
Center To Center Distance Between Mounting Facilities Parallel To Length:
4.375 inches single mounting facility single center group
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.ABKR
Center To Center Distance Between Mounting Facilities Parallel To Width:
3.485 inches single mounting facility single center group and 3.515 inches single mounting facility single center group
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
4.437 inches
MRC:
The length of a straight line which passes through the center of a mounting hole,and terminates at the circumference.ABTB
Mounting Hole Diameter:
0.260 inches single group
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
47.0 hertz single component and 420.0 hertz single component
MRC:
The relationship of the phase input to the phase output of an alternating current.ACZC
Input-output Phase Relationship:
Single phase to single phase single component
MRC:
The means by which a protective metal screen,plate,or inclosure is placed around or between the windings of an item to prevent electrostatic or magnetic coupling.ACZX
Winding Shielding Method:
Internal shield brought out to terminal single component
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
5.000 inches
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
155.0 degrees celsius
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
4 single group
MRC:
The means of attaching the item.AXGY
Mounting Method:
Unthreaded hole single group
MRC:
The purpose and the total number of individual (not electrically connected) windings designed to perform in a transformer.BPLC
Winding Function And Quantity:
2 primary single component and 4 secondary single component
MRC:
The amount of operating current for which the winding is designed.CRBZ
Winding Operating Current:
1.0 amperes dc single component 3rd secondary
MRC:
The amount of operating current for which the winding is designed.CRBZ
Winding Operating Current:
4.6 amperes dc single component 2nd secondary
MRC:
The amount of operating current for which the winding is designed.CRBZ
Winding Operating Current:
25.0 milliamperes dc single component 1st secondary
MRC:
The maximum power for which the winding of the item is rated.CRMJ
Winding Power Rating:
16.0 volts-amperes single component 3rd secondary
MRC:
The maximum power for which the winding of the item is rated.CRMJ
Winding Power Rating:
2.75 volts-amperes single component 1st secondary
MRC:
The maximum power for which the winding of the item is rated.CRMJ
Winding Power Rating:
43.24 volts-amperes single component 2nd secondary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
102.00 dc volts single component 1st secondary and 110.00 dc volts single component 1st secondary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
14.80 dc volts single component 3rd secondary and 16.00 dc volts single component 3rd secondary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
240.00 ac volts single component all primary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
32.00 dc volts single component 4th secondary and 34.00 dc volts single component 4th secondary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
8.70 dc volts single component 2nd secondary and 9.40 dc volts single component 2nd secondary
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
18 tab, solder lug