Part Number 4444-5001G1

Electrical Dummy Load

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
4444-5001g1
Demil:
Yes - DEMIL/MLI
Shelf Life:
UOM:
NIIN:
009046240

Part Information
1.25-1 vswr maximum over freq range, pressure type, tested to 20 psig of air without damage or leakage

NSN
National Stock Number:
5985-00-904-6240 5985009046240
TXT
Description:
Electrical Dummy Load
INC
INC
Item Name Code:
00335
INC
COM
Compliance:
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
18.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
5.437 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
8.687 inches
MRC:
The range of complete cyclic changes,per unit of time,for which an item is rated.AFGQ
Frequency Range Rating:
+1250.000/+1350.000 megahertz
MRC:
The ratio of the maximum to the minimum amplitude of pressure /voltage/ measured along the path of the waves.AHTW
Voltage Standing Wave Ratio:
1.25
MRC:
The amount of electrical energy that can be dissipated.AJDB
Power Rating:
2.500 megawatts peak and 800.000 watts average
MRC:
Indicates the type of facility provided on the device for attaching to another item.AKRZ
Termination Type:
Waveguide flange
MRC:
The nominal exerted outward force,per unit of area,for which the item is designed.AWNC
Internal Operating Pressure:
15.0 pounds per square inch gage
MRC:
The means of cooling used to maintain the required operating temperature of the item.BFMF
Cooling Method:
Self-cooled
MRC:
Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
Functional Description:
Residual load for polarizer, circular linear (radar), orthogonal port during the mode switch position when one transmitter is in dummy load and the other transmitter is in radiating