Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
460b
Demil:
No
Shelf Life:
UOM:
NIIN:
000569560
NSN
National Stock Number:
6625-00-056-9560 6625000569560
TXT
Description:
Multiple Scale Meter
INC
INC
Item Name Code:
62222
MRC:
The type of electrical circuit in which the item is designed to be used.AACT
Circuit Current For Which Designed:
Dc
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
2.055 inches
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.ABKQ
Center To Center Distance Between Mounting Facilities Parallel To Length:
4.000 inches
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.ABKR
Center To Center Distance Between Mounting Facilities Parallel To Width:
3.560 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
4.160 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
4.620 inches
MRC:
A measurement of the longest dimension of the mounting stud,in distinction from width.ADAG
Mounting Stud Length:
0.500 inches
MRC:
The name and number of those parts furnished with the item of supply that have not been specified elsewhere.AKYN
Furnished Items And Quantity:
Nut 8; washer 10
MRC:
Indicates the type of device used to register the condition(s).AMKD
Indicator Type:
Dial w/pointer
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Panel
MRC:
The style designation indicating the configuration that most nearly corresponds to the arrangement of the mounting.ANRL
Mounting Arrangement Style:
Four hole/stud rectangular/square
MRC:
The hue or tint of the dial scale marking(s).APMM
Dial Scale Marking Color:
Black single indicator all ranges
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
-2.0/+2.0 at full scale single indicator all ranges
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
-2.0 to 2.0 at full scale single indicator all ranges
MRC:
A measurement between the mounting flange and the extremity of the meter, indistinction from height.APST
Meter Depth Behind Mounting Flange:
1.000 inches
MRC:
The length of a straight line which passes through the center of the meter body behind the mounting flange, and terminates at the circumference.APSW
Meter Body Diameter Behind Mounting Flange:
2.720 inches
MRC:
Indicates the type of movement provided.AQEC
Movement Type:
Moving coil, permanent magnet
MRC:
The hue or tint of the background.AQFY
Background Color:
White single indicator all ranges
MRC:
The hue or tint of the pointer.ASSS
Pointer Color:
Black single indicator all ranges
MRC:
The source of power which provides the energy required for the operation of the item.AWZJ
Power Source:
External
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
4 threaded stud
MRC:
Indicates the type of graduations provided on the scale.BHDC
Scale Graduation Type:
Nonlinear single indicator all ranges
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
-0.0/+1.0 milliwatts single indicator 3rd range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
-0.0/+3.0 milliwatts single indicator 2nd range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
-10.0/+0.0 decibels above or below one milliwatt single indicator 1st range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
-0.0 to 1.0 milliwatts single indicator 3rd range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
-0.0 to 3.0 milliwatts single indicator 2nd range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
-10.0 to 0.0 decibels above or below one milliwatt single indicator 1st range
MRC:
The length of a straight line which passes through the center of a mounting stud,and terminates at the circumference.BLKZ
Mounting Stud Diameter:
0.134 inches
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Zero adjuster
MRC:
The means employed to suspend the movement of the item.CTQL
Movement Suspension Method:
Jewel pivot base
MRC:
The means provided for electrical connection to a circuit and the number of each type of connection.CTTD
Circuit Attachment Method And Quantity:
2 solder lug and 2 threaded stud
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Plastic
MRC:
An indication of the nuclear hardness criticality of the item.NHCF
Nuclear Hardness Critical Feature:
Nonhardened
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Rectangular flush mtg
MRC:
The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV