Part Number 462A011-342

S Electrical Insulation Sleeving

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
462a011-342
Demil:
No
Shelf Life:
UOM:
NIIN:
012350784

Part Information
Inside coated with adhesive

NSN
National Stock Number:
5970-01-235-0784 5970012350784
TXT
Description:
S Electrical Insulation Sleeving
INC
INC
Item Name Code:
61626
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.ABJH
Tempurature Rating:
-55.0 degrees celsius
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Corrosion resistant and flame resistant and mildew resistant and solvent resistant and water resistant
MRC:
None.AFZU
Main Body Inside Diameter:
0.240 inches after unrestricted recovery
MRC:
None.AFZU
Main Body Inside Diameter:
0.520 inches as supplied
MRC:
None.AFZV
First Branch Inside Diameter:
0.120 inches after unrestricted recovery
MRC:
None.AFZV
First Branch Inside Diameter:
0.260 inches as supplied
MRC:
None.AFZW
Second Branch Inside Diameter:
0.120 inches after unrestricted recovery
MRC:
None.AFZW
Second Branch Inside Diameter:
0.260 inches as supplied
MRC:
None.AFZX
Third Branch Inside Diameter:
0.120 inches after unrestricted recovery
MRC:
None.AFZX
Third Branch Inside Diameter:
0.260 inches as supplied
MRC:
None.AGAA
Distance From Intersecting Centerline Of Main Body To End Of First Branch:
1.000 inches after unrestricted recovery
MRC:
None.AGAB
Main Body Wall Thickness:
0.060 inches after unrestricted recovery
MRC:
None.AGAC
First Branch Wall Thickness:
0.040 inches after unrestricted recovery
MRC:
None.AGAD
Second Branch Wall Thickness:
0.040 inches after unrestricted recovery
MRC:
None.AGAE
Third Branch Wall Thickness:
0.040 inches after unrestricted recovery
MRC:
None.AGAG
Distance From Edge Of Main Body To Intersecting Centerlines:
0.820 inches after unrestricted recovery
MRC:
None.AGAH
Main Bodylength:
1.820 inches after unrestricted recovery
MRC:
None.AGAQ
Angle Between Main Body And First Branch Centerlines In Deg:
10.0 as supplied
MRC:
None.AGAQ
Angle Between Main Body And First Branch Centerlines In Deg:
30.0 after unrestricted recovery
MRC:
The maximum rated load in tension applied in a longitudinal direction,per unit of cross-sectional area,that the material can withstand without rupture.CQBC
Min. Tensile Strength (psi):
1500 pounds per square inch
MRC:
Flexible,capable of being bent,turned or twisted,within limits,without breaking,or rigid,resisting change of form,inflexible.FLEX
Flexibility:
Semirigid
MRC:
A characteristic of light that can be specified in terms of luminance,dominant wavelength,and purity.HUES
Color:
Black
MRC:
The element,compound,or mixture of which an item is fabricated,excluding any surface treatment.MATL
Material:
Plastic, polyolefin, rt-301, raychem corporation and plastic, polyolefin, mpp-262, high voltage engineering corp
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Plastic, polyolefin, rt-301, raychem corporation and plastic, polyolefin, mpp-262, high voltage engineering corp
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Transition-1 to 3 cables
MRC:
The maximum potential gradient the insulating material can withstand,per unit thickness,without rupture.UKBG
Dielectric Material Voltage Rating Per Unit Thickness:
200.0 volts per military /0.001 inch/

Similar S Electrical Insulation Sleevings

« Electrical Insulators and Insulating Materials Catalog
Compare Now »
Clear | Hide