Part Number
DEMIL
Shelf Life
UOM
NIIN
Part Information
Groups six and seven are the same materials and color as groups one through five, first group color is black, second group color is white, third group color is red, fourth pair color group is green, fifth group pair is orange, sixth pair is blue, and seventh group pair is white/black
NSN
National Stock Number:
TXT
Description:
Electrical Power Cable Assembly
MRC:
The style designation indicating the configuration that most nearly corresponds to the cross-sectional shape of the item.AAGR
Cross Sectional Shape:
Round
MRC:
A measurement of the longest dimension of an item,in distinction from width.AAJU
Overall Length:
160.000 feet
MRC:
The length of a straight line which passes through the center of a cross section,and terminates at the outside circumference.ADVL
Cross Section Outside Diameter:
2.250 inches
MRC:
Indicates the type of facility provided on the device for attaching to another item.AKRZ
Termination Type:
Unprocessed 2nd end all conductors
MRC:
Indicates the type of facility provided on the device for attaching to another item.AKRZ
Termination Type:
Connector receptacle 1st end all conductors
MRC:
The number of electrical conductors included on the item.AMQN
Conductor Quantity:
14
MRC:
The number of strands per conductor.BLNZ
Strand Quantity Per Conductor:
7 all conductors
MRC:
The fabricated form of the conductor.CXCW
Conductor Form:
Stranded all conductors
MRC:
The designation used to describe the round stranded or round solid conductor size.CXDC
Round Conductor Size:
22 awg all conductors
MRC:
The american wire gage size of the individual strands of wire used in each stranded conductor.CXDG
Strand Awg Size Per Conductor:
30 all conductors
MRC:
The arrangement and number of arrangements of the conductors.CXDQ
Conductor Arrangement And Quantity:
7 twisted pair
MRC:
The identification of the conductors within a group.CXFG
Conductor Sequence Within Groups:
All conductors first group
MRC:
The identification of the conductors within a group.CXFG
Conductor Sequence Within Groups:
All conductors second group
MRC:
The identifying reference number assigned to the terminal(s) by the manufacturer.CXGG
Terminal Manufacturer Identifying Reference Number:
185615-1 1st end all conductors
MRC:
The five-position commercial and government entity code for the manufacturer of the terminal.CXGN
Terminal Commercial And Government Entity Code:
37695 1st end all conductors
MRC:
A measurement of the longest dimension of an individual conductor,in distinction from width.CXGW
Individual Conductor Length:
1.500 inches 1st end all conductors
MRC:
A characteristic of light that can be specified in terms of luminance,dominant wavelength,and purity.HUES
Color:
Black 1st position cover second conductor
MRC:
A characteristic of light that can be specified in terms of luminance,dominant wavelength,and purity.HUES
Color:
White 1st position cover first conductor
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper core conductor all conductors
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Plastic polyethylene terephthalate 1st position primary insulation all conductors
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Plastic polyhexamethylene adipamide 2nd position jacket all conductors
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Tin alloy 1st position conductor all conductors
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Tin core conductor all conductors
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Internal connector