Part Number 475280

Blood Gas Analyzer

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
475280
Demil:
No
Shelf Life:
UOM:
NIIN:
013144292

Part Information
Analyzer blood gas volumetric 115/230v 50/60hz single phase auto

NSN
National Stock Number:
6630-01-314-4292 6630013144292
TXT
Description:
Blood Gas Analyzer
INC
INC
Item Name Code:
38049
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Between 50.0 hertz and 60.0 hertz
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
115.0 and 230.0
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Automatic; c/o electrodes, reagents, initial calibration and supplies necessary for start up operation; calculates and measures ph, po2 and base excess; bicarbonate and 02 saturation; permits the introduction of samples of venous blood, arterial blood and expired gas
MRC:
Characteristics or qualities of an item,not covered in any other requirement,which are considered essential information for one or more functions excluding nsn assignment.SUPP
Supplementary Features:
Xcentral procurement of medical equipment "cenprome" service controlled and managed item; requisition using published customer order list (col) only in accordance w/service or agency instructions; service points of contact for information and requisitioning instructions are: u.S. Army medical materiel agency, usamma/sgmma-om, ft. Detrick, md 21702-5001, av 343-7403 commercial (301) 619-7403; air force medical logistics office, afmlo/fom, ft. Detrick md 21702-5001, av 343-7487 commercial (301) 619-7487; naval medical materiel support command, navmedmat suppcom, ft. Detrick md 21702-5001, av 343-7117 commercial (301) 619-7117; requisitioner should specify the voltage and frequency required; 115 vac, 60 hz, 115 vac, 50 hz; 230 vac, 50 hz, 230 vac, 60 hz
MRC:
The document designator of the specification or standard which established the item of supply.ZZZK
Specification Data:
51404-dla120-92-d-8084 government specification