Part Number 4C3500-3A-NBH-1991

Static Frequency Converter

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
4c3500-3a-nbh-1991
Demil:
Yes - DEMIL/MLI
Shelf Life:
UOM:
NIIN:
015758604

Part Information
Frequency converter

NSN
National Stock Number:
6130-01-575-8604 6130015758604
TXT
Description:
Static Frequency Converter
INC
INC
Item Name Code:
00330
INC
COM
Compliance:
MRC:
A measurement taken at right angles to the length of an item,in distinction from thickness.ABGL
Width:
7.000 inches
MRC:
A measurement of the longest dimension of any object,in distinction from width.ABRY
Length:
16.000 inches
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Airbus a330/a340
MRC:
The number of input alternating current phase(s).ANPM
Input Phase:
Three
MRC:
The ratio of permissible frequency deviation from the controlled constant value,expressed in percent.ANRQ
Frequency Regulation Percent:
5.0
MRC:
An indication of the accuracy of an item,expressed in percent.APFN
Accuracy In Percent:
87.0
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
Between 320.0 hertz and 700.0 hertz
MRC:
The number of complete cyclic changes,per unit of time,for which the output is rated.APTS
Output Frequency Rating:
50.0 hertz
MRC:
An indication of the line to ground voltage.AQAR
Line To Ground Voltage:
Between 108.0 volts and 118.0 volts
MRC:
The means of attaching the item.AXGY
Mounting Method:
Rack and cradle in cabinet
MRC:
The amount of apparent power,as distinguished from true power,for which the item is rated.BGQS
Volt-ampere Rating:
3500.0 volt-ampere
MRC:
The total line to line output alternating current potential for which the item is rated.BGQT
Line To Line Ac Output Voltage Rating:
230.0 volts
MRC:
The value,or range of values,of alternating current potential for which the input of an item is rated.BGQW
Ac Input Voltage Rating:
Between 115.0 volts and 200.0 volts
MRC:
An indication of whether or not overload protection is provided.BGQX
Overload Protection:
Provided
MRC:
An indication of whether or not a radio interference filter is provided.BGQY
Radio Interference Filter:
Provided
MRC:
The number of alternating current phases.FAAZ
Phase:
Single and three
MRC:
A measurement from the bottom to the top of an object,in distinction from depth.HGTH
Height:
5.000 inches
MRC:
Test conditions and ratings,or environmental and performance requirements that are different,more critical,or more specific than those specified in a governing test data document.SPCL
Special Test Features:
Rtca do-160c sec4/6/7/8/9/10/11/12/13/14/15/18/20/22
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
81348-mil-std-801d standard (includes industry or association standards, individual manufactureer standards, etc.).

Similar Static Frequency Converters

« Converters Electrical Nonrotating Catalog
Compare Now »
Clear | Hide