Part Number 50-1-1-501

Non Wire Wound Variable Resistor
Stock Availability  condition code chart

Part number 50-1-1-501 is in stock in the following quantities and conditions.

  • NS: 2
  • NE: 2

Note: Availability of this item was last updated 07/25/2024 and may have changed since then. Request a quote for up to date pricing and availability.

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
50-1-1-501
Demil:
No
Shelf Life:
UOM:
NIIN:
007110617

Part Information
Sealed to permit cleaning in common solvents

NSN
National Stock Number:
5905-00-711-0617 5905007110617
TXT
Description:
Non Wire Wound Variable Resistor
INC
INC
Item Name Code:
37406
MRC:
The number of individual elements.AAPN
Section Quantity:
1
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Rectangular w/mounting holes
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
0.455 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
Between 0.370 inches and 0.380 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
Between 0.185 inches and 0.195 inches
MRC:
The length of a straight line which passes through the center of a mounting hole,and terminates at the circumference.ABTB
Mounting Hole Diameter:
Between 0.072 inches and 0.082 inches
MRC:
The length of a straight line which passes through the center of a shaft,and terminates at the circumference.ABWV
Shaft Diameter:
0.093 inches
MRC:
A measurement of the longest dimension of the shaft,in distinction from width.ABXF
Shaft Length:
0.080 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
Between 0.370 inches and 0.380 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
Between 0.185 inches and 0.195 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
Between 0.370 inches and 0.380 inches
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the shaft.AEDX
Shaft Style:
Round, slotted
MRC:
Indicates the type of facility or arrangement provided for moving the variable contact(s).AEFD
Actuator Type:
Single shaft
MRC:
That part of the total rotational travel of the actuator that produces a change in output,expressed in degree angular rotation.AEFH
Effective Electrical Rotation In Deg Angular Rotation:
Between 8280.0 and 9720.0
MRC:
The maximum amount of turning force required to initiate the actuator movement.AEFK
Maximum Starting Torque:
5.00 inch-ounces
MRC:
None.AGTP
Lateral Distance Between Mounting Hole Centers:
Between 0.370 inches and 0.380 inches
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
2
MRC:
The position of the terminal/s/ for making connection to an item.APXH
Terminal Location:
Rear end
MRC:
The means of attaching the item.AXGY
Mounting Method:
Unthreaded hole
MRC:
A measure of the opposition to the flow of direct or alternating current per section.CQCC
Electrical Resistance Per Section:
500.0 ohms single section
MRC:
The measurement of the rotary mechanical motion of the actuating shaft of an item,expressed in degrees.CQCK
Rotary Actuator Travel In Angular Deg:
Between 8280.0 and 9720.0
MRC:
The ambient temperature at which the power dissipation of each section is derated to zero percent of the full rated power.CQGN
Ambient Tempurature In Deg Celsius Per Section At Zero Percent Rated Power:
150.0 single section
MRC:
A constant that represents the proportionate change in resistance caused by a change in temperature per section,expressed in parts per million per degree celsius.CRFJ
Tempurature Coefficient Of Resistance Per Section In Ppm Per Deg Celsius:
-70.0/+70.0 single section
MRC:
A constant that represents the proportionate change in resistance caused by a change in temperature per section,expressed in parts per million per degree celsius.CRFJ
Tempurature Coefficient Of Resistance Per Section In Ppm Per Deg Celsius:
-70.0 to 70.0 single section
MRC:
The maximum amount of electrical energy that can be expended per section,expressed in watts.CRGD
Power Dissipation Rating Per Section In Watts:
1.0 free air single section
MRC:
The limits of permissible variation in the electrical resistance value per section of an item from its rated value,expressed in percent.CRSS
Resistance Tolerance Per Section In Percent:
-5.0/+5.0 single section
MRC:
The limits of permissible variation in the electrical resistance value per section of an item from its rated value,expressed in percent.CRSS
Resistance Tolerance Per Section In Percent:
-5.0 to 5.0 single section
MRC:
The feature that controls the actuator travel.CRSX
Actuator Travel Control Feature:
Continuous motion
MRC:
The ambient temperature,expressed in degrees celsius,of the medium surrounding each section at which it can be operated continuously at full rated power.CSDH
Ambient Tempurature In Deg Celsius Per Section At Full Rated Power:
70.0 single section
MRC:
The rate of change and distribution of resistance per section,in relation to the rotation of the control shaft,which establishes a standard taper curve designated by an alphabetic character and accepted for common usage.CSDL
Standard Taper Curve Per Section:
A single section
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
3 wire lead

Similar Non Wire Wound Variable Resistors

« Resistors Catalog
Compare Now »
Clear | Hide