Part Number
DEMIL
Shelf Life
UOM
NIIN
Part Information
Mtg holes 0.41 in. Diameter counter bore
NSN
National Stock Number:
TXT
Description:
Instrument Shunt
MRC:
The number of mounting provisions provided.ABDS
Mounting Provision Quantity:
2
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
7.980 inches
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.ABKQ
Center To Center Distance Between Mounting Facilities Parallel To Length:
2.120 inches
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.ABKR
Center To Center Distance Between Mounting Facilities Parallel To Width:
4.240 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
2.150 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
5.000 inches
MRC:
The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.AEBV
Unthreaded Mounting Hole Diameter:
0.250 inches
MRC:
The name and number of those parts furnished with the item of supply that have not been specified elsewhere.AKYN
Furnished Items And Quantity:
Base 1; nut 2
MRC:
Indicates the designed use of the item.ALBY
Usage Design:
External
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
-0.25/+0.25 at full scale
MRC:
The element,compound,or mixture of which the element is fabricated,excluding any surface treatment.AQCW
Element Material:
Copper-manganese-nickel alloy
MRC:
The means of attaching the item.AXGY
Mounting Method:
Unthreaded hole
MRC:
Indicates the location of the terminal/s/ on the item.CQTM
Terminal Location:
End
MRC:
The loss of potential resulting from the inherent opposition to the flow of electricity across the item,expressed in millivolts.CRCM
Voltage Drop In Millivolts:
50.0
MRC:
Indicates the type of current and the rated value for which the item is designed.CRCT
Current Rating And Type:
1000.0 amperes dc
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
2 eyelet
MRC:
The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV
Fsc Application Data:
Elec. Elect. Properties measuring and test instruments