Part Number
DEMIL
Shelf Life
UOM
NIIN
NSN
National Stock Number:
TXT
Description:
Radio Test Set
MRC:
A measurement taken at right angles to the length of an item,in distinction from thickness.ABGL
Width:
18.800 inches
MRC:
A measurement of the longest dimension of any object,in distinction from width.ABRY
Length:
21.800 inches
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
Between 6.3 volts and 115.0 volts
MRC:
The value,or range of values,of direct current potential for which the item is rated.ACYR
Dc Voltage Rating:
Between 27.5 volts and 600.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Between 60.0 hertz and 400.0 hertz
MRC:
The principal parts that are included in an assembled unit.AEAS
Major Components:
Cable; motor drive; oscillator adapter assembly
MRC:
The number of parts supplied with the item which may be required for application.AFHS
Accessory Component Quantity:
1 and 1 and 1
MRC:
The name of the government agency or commercial organization that controls the manufacture of the accessory item.AKVY
Accessory Controlling Agency:
Collins radio co
MRC:
The specific number used to identify the accessory.AKVZ
Accessory Identifying Number:
5406605002 part no. And 5405764005 part no. And 5412713004 part no.
MRC:
An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
Internal Battery Accommodation:
Not included
MRC:
The element,compound,or mixture of which the item is fabricated,excluding any surface treatment,and its location.ANNQ
Material And Location:
Steel housing
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
Single item w/housing
MRC:
Indicates the type of test for which the item is designed.AQXY
Test Type For Which Designed:
Tests go-no-go signal for all plug in modules used in collins tranceiver type 618s1 and 618s1a
MRC:
The testing functions such as range,sensitivity,output,and the like,for which the item is designed.AQXZ
Operating Test Capability:
Meter range 0 to 1 ma two crystal oscillators range 1.75 to 25 mc 250 kc crystal oscillators
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
A measurement from the bottom to the top of an object,in distinction from depth.HGTH
Height:
13.000 inches