Part Number 524-019605

Reference Electrode

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
524-019605
Demil:
No
Shelf Life:
UOM:
NIIN:
011902735

Part Information
Slow and predictable flow rate; recommended for pressurized application; pressure range: 0 to 150 psig; not to used in solutions where strong oxidations/reductants are present; used for series three electrode stations

NSN
National Stock Number:
6630-01-190-2735 6630011902735
TXT
Description:
Reference Electrode
INC
INC
Item Name Code:
40339
MRC:
The length of a straight line which passes through the center of the body,and terminates at the circumference.ABPM
Body Diameter:
0.850 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
4.000 inches
MRC:
The name and number of parts supplied with the item which may be required for application.AKYD
Accessory Components And Quantity:
Cap 191068, 1ea; retainer 193543, 1 ea; membrane 777182, 1 ea; holder 777183, 1ea; gland 192535, 1ea; diaphragm 193976, 1ea; washer 777199, 1ea; screw diaphragm 191066, 1ea; o ring 777551, 1ea; o ring 777502, 1ea; o ring 777545, 2ea; electrode instruction sheet 1ea
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Shielded
MRC:
The chemical compound or mechanical mixture properties of which the body is fabricated.CQRG
Body Material:
Glass and plastic epoxy clear
MRC:
Indicates the type of instrument that the item will be used with,as suggested by either government specification or manufacturer.CYHA
Instrument Type For Which Designed:
Ph meter
MRC:
The minus and/or plus degrees of temperature the item can withstand without giving erroneous assay data.CYHE
Operating Temperature Range:
5.0 degrees celsius minus and 100.0 degrees celsius plus
MRC:
Indicates the type of junction employed in the item,to prevent unwanted ion interference.CYHG
Err Default:
Err default
MRC:
Indicates the type of internal electrode element employed to read a specific ion concentration in a sample/specimen or solution.CYHH
Internal Reference Element Type:
Silver chloride/potassium
MRC:
Indicates the type and concentration of a solution needed to activate the item.CYHK
Err Default:
Err default

Similar Reference Electrodes

« Chemical Analysis Instruments Catalog
Compare Now »
Clear | Hide