Part Number
DEMIL
Shelf Life
UOM
NIIN
NSN
National Stock Number:
TXT
Description:
Safety Relief Valve
MRC:
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.AAJD
Thread Class:
3b all ends
MRC:
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.AAJF
Thread Direction:
Right-hand all ends
MRC:
The part that controls the flow through the item.ADQU
Flow Control Device:
Poppet
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
250.0 degrees fahrenheit single response
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the connection.AHNC
Connection Style:
G4 gasket sea (boss) all ends
MRC:
The means used to control the operation of the valve.AQLR
Valve Operation Method:
Automatic
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
Threaded internal boss all ends
MRC:
The number of threads on the item per linear inch measured on a line parallel to the thread axis.CMLP
Thready Qty Per Inch (tpi):
12 all ends
MRC:
The minimum to maximum pressures at which the item may be set to open.CQCY
Adjustable Pressure Range:
+10.0/+2400.0 pounds per square inch
MRC:
The maximum pressure at which the item is rated for operation.CQGM
Maximum Operating Pressure:
2500.0 pounds per square inch single response
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
1.062 inches all ends
MRC:
The predetermined pressure at which the item is calibrated to open.CSDC
Opening Pressure Setting:
55.0 pounds per square inch
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Aluminum alloy 2024 body
MRC:
The type of media for which the item is designed.MEDA
Media For Which Designed:
Refrigerant 12 4th response
MRC:
The type of media for which the item is designed.MEDA
Media For Which Designed:
Acetylene 2nd response
MRC:
The type of media for which the item is designed.MEDA
Media For Which Designed:
Air 1st response
MRC:
The type of media for which the item is designed.MEDA
Media For Which Designed:
Ammonia, gaseous 3rd response
MRC:
The type of media for which the item is designed.MEDA
Media For Which Designed:
Hydrogen 5th response
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Err-090
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Un all ends