Part Number
DEMIL
Shelf Life
UOM
NIIN
NSN
National Stock Number:
TXT
Description:
Light-switch
MRC:
The specific commercial rating which classes the item as to what degree the item will withstand environmental elements and/or hazardous locations.ABFE
Hazardous Locations/environmental Protection:
Raintight-nema type 3r
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
2.310 inches
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
0.938 inches
MRC:
Indicates the type of switch included in the item.AEEA
Switch Type:
Push
MRC:
Indicates the type of lamp base the item will accommodate.AEUJ
Lamp Base Type Accommodated:
Midget flanged
MRC:
The designation that describes the size and configuration of a lamp bulb.AEWU
Lamp Bulb Size Designator:
T1-3/4
MRC:
The hue or tint of the lens.AEXD
Lens Color:
Red
MRC:
The designation that identifies the schematic diagram of the electrical configuration of a switch including the number of switching poles or forms.AKDY
Switch Contact Arrangement:
2 two circuit, double break/double make, one position momentary
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
1
MRC:
The element,compound,or mixture of which the item is fabricated,excluding any surface treatment,and its location.ANNQ
Material And Location:
Aluminum cover
MRC:
The plating,dip,and/or coating that cannot be wiped off.plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects the surface of the item and its location.ANNR
Surface Treatment And Location:
Anodized cover
MRC:
The amount of operating voltage,expressed in volts.APHA
Operating Voltage In Volts:
28.0
MRC:
The total electrical voltage of the lamp,expressed in volts.ARQK
Lamp Voltage Rating In Volts:
28.0
MRC:
The thread series,thread major/maximum diameter,and the number of threads per measurement scale of the mounting facility.AWAZ
Mounting Facility Thread Size:
15/32-32 uns
MRC:
The means of attaching the item.AXGY
Mounting Method:
Threaded bushing
MRC:
The physical configuration and its location on the item.AZCQ
Shape And Location:
Round cover
MRC:
Indicates the type and amount of electrical flow at which the item is designed to operate,expressed in amperes.AZCS
Current Type And Rating In Amps:
10.00 dc
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Lens
MRC:
Markings included on an item for the purpose of offering instructions or warnings or to indicate the purpose,function,or application of the item.excludes manufacturers part numbers,symbols,or the like.MARK
Special Markings:
2