Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
573a517-18a
Demil:
No
Shelf Life:
UOM:
NIIN:
006327081
NSN
National Stock Number:
5945-00-632-7081 5945006327081
TXT
Description:
Electromagnetic Relay
INC
INC
Item Name Code:
32512
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
8.250 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
11.750 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
6.500 inches
MRC:
The measure of sensitivity of the item to be packaged. a factor used by packaging engineers in devising proper cushioning in a package.AFJN
Fragility Factor:
Moderately rugged
MRC:
The number of individual /not electrically connected/ windings.AKDX
Winding Quantity:
1
MRC:
The purpose for which the item is designed.AKSL
Purpose For Which Designed:
General
MRC:
The number of coils included on the item.APCN
Coil Quantity:
1
MRC:
Indicates the type of duty provided.APNP
Duty Type:
Continuous
MRC:
The means of quenching an arc.APNQ
Arc Quenching Method:
Air
MRC:
Indicates the type of storage space required for an item in order to provide the degree of protection necessary to maintain serviceability standards.BBRG
Storage Type:
General purpose warehouse
MRC:
The designation that identifies the schematic diagram of the electrical configuration of the main nonpile-up contacts including the number of poles or forms.CRNG
Nonpile-up Main Contact Arrangement:
3 pole, single throw, normally closed, momentary action
MRC:
The required current value,applied to the energizing element,at which the switching mechanism or actuator element must have assumed a fully operated position.CRPQ
Operating Current Rating And Type:
18.0 amperes ac single winding and 8.0 amperes ac single winding
MRC:
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.CTDL
Main Contact Load Current Rating At Maximum Rated Voltage:
27.0 amperes ac resistive load

Similar Electromagnetic Relaies