Part Number
DEMIL
Shelf Life
UOM
NIIN
NSN
National Stock Number:
TXT
Description:
Radio Frequency Transformer
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The number of turns of conductive material forming the winding.ABHY
Turn Quantity:
6 single component 2nd secondary
MRC:
The number of turns of conductive material forming the winding.ABHY
Turn Quantity:
7 single component 1st secondary
MRC:
The number of turns of conductive material forming the winding.ABHY
Turn Quantity:
7 single component 3rd secondary
MRC:
The number of turns of conductive material forming the winding.ABHY
Turn Quantity:
7 single component single primary
MRC:
The length of a straight line which passes through the center of a mounting hole,and terminates at the circumference.ABTB
Mounting Hole Diameter:
0.010 inches single group
MRC:
The value(s) of inductance inherent in the item.ACYV
Inductance Rating:
0.09 microhenries single component 2nd secondary
MRC:
The value(s) of inductance inherent in the item.ACYV
Inductance Rating:
0.11 microhenries single component 1st secondary
MRC:
The value(s) of inductance inherent in the item.ACYV
Inductance Rating:
0.11 microhenries single component 3rd secondary
MRC:
The value(s) of inductance inherent in the item.ACYV
Inductance Rating:
0.11 microhenries single component single primary
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
172.0 megahertz single component
MRC:
Indicates the type of support on which the coil is wound.ACZP
Coil Form Type:
Solid single component
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
0.180 inches
MRC:
The length of a straight line which passes through the center of the body,and terminates at the outside circumference.ADAR
Body Outside Diameter:
0.300 inches
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
85.0 degrees celsius
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Open
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
1 single group
MRC:
The means of attaching the item.AXGY
Mounting Method:
Unthreaded hole single group
MRC:
The means by which the rating is determined.BKPL
Rating Method:
Electrical single component all secondary and winding turns single component all secondary
MRC:
The means by which the rating is determined.BKPL
Rating Method:
Electrical single component single primary and winding turns single component single primary
MRC:
The purpose and the total number of individual (not electrically connected) windings designed to perform in a transformer.BPLC
Winding Function And Quantity:
1 primary single component and 3 secondary single component
MRC:
The size of the conductor which forms the winding on the item.CQPZ
Winding Conductor Size:
0.00795 inches american wire gage single component all secondary
MRC:
The size of the conductor which forms the winding on the item.CQPZ
Winding Conductor Size:
0.00795 inches american wire gage single component single primary
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
8 wire lead