Proof pressures: supply 6000 psi, control 6000psi, return 4000 psi; burst pressures: supply 10, 000 psi, control 10, 000 psi, return 8, 000 psi; oil mil-h-5606; oil temp -65 to +275 degrees feh; ambient temp -65 to +143 degrees feh; flow characteristics: supply to control flow shall be .56 gpm min @ 4000 psid, control to return flow shall be .56 gpm min at 4000 psid; internal leakage shall not exceed .02 gpm max; for nha info for model cdas pdu02 refer to drawing 747985
Part Number | RNVC | RNAAC | DAC | CAGE |
---|---|---|---|---|
5909782 | 2 | ZZ | 2 | 99167 |
101070 | 9 | ZZ | 2 | 53541 |
Code | Definition |
---|---|
FN | Factory New. Parts manufactured by then OEM and includes manufacturer certification. |
NE | New. Parts manufactured by the OEM. May include manufacturer certification or company certification. |
NS | New Surplus. New material item purchased from excess inventory. |
OH | Overhauled. Product has been rebuilt and tested in accordance with the manufacturer's specifications by a repair shop (MRO). |
SV | Serviceable product. |
AR | As Removed. Product removed from aircraft or platform with no guarentee on the functionality of the part. |
RP | Repairable. Product can be repaired by a MRO and be given a FAA 8130 or EASA Form 1 certification. |