Part Number 59B81111

Electromagnetic Relay

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
59b81111
Demil:
No
Shelf Life:
UOM:
NIIN:
002438113
NSN
National Stock Number:
5945-00-243-8113 5945002438113
TXT
Description:
Electromagnetic Relay
INC
INC
Item Name Code:
32512
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
2.310 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
1.930 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
1.620 inches
MRC:
The number of individual /not electrically connected/ windings.AKDX
Winding Quantity:
1
MRC:
The number of coils included on the item.APCN
Coil Quantity:
1
MRC:
The measured opposition to the flow of direct current offered by the item winding.APNA
Winding Dc Resistance Rating:
17.0 ohms single winding
MRC:
Indicates the type of duty provided.APNP
Duty Type:
Continuous
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
2 threaded hole single mounting facility
MRC:
The general configuration and relative position of the facilities provided for mounting the item.CQYJ
Mounting Facility Pattern:
In-line single mounting facility
MRC:
The amount and type of voltage required at designated temperature to be applied to the input or energizing element of the item to ensure normal operation of the switching elements.CSXF
Operating Voltage Rating And Type At Specificationified Temp:
6.0 volts dc 25 degrees celsius single winding
MRC:
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.CTDL
Main Contact Load Current Rating At Maximum Rated Voltage:
15.0 amperes dc resistive load
MRC:
The highest voltage at which the main contacts are rated for normal operation,expressed in volts.CWAB
Main Contact Maximum Voltage Rating In Volts:
6.0 dc
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
4 wire lead energizing element
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
2 wire lead contacts

Similar Electromagnetic Relaies

« Relays and Solenoids Catalog
  • 6N040
    NSN: 5945-00-243-9164
  • 53462
    NSN: 5945-00-243-9165
  • 601B
    NSN: 5945-00-243-9170
  • K102-1
    NSN: 5945-00-243-9282
  • 6-172-9
    NSN: 5945-00-243-9284
Compare Now »