Part Number
DEMIL
Shelf Life
UOM
NIIN
NSN
National Stock Number:
TXT
Description:
Safety Relief Valve
MRC:
The part that controls the flow through the item.ADQU
Flow Control Device:
Disk
MRC:
Indicates the type of housing on the item that accommodates the stem packing or spring.ADSR
Bonnet Type:
Exposed spring
MRC:
The means by which the bonnet is attached to the item.ADST
Bonnet Attachment Method:
Bolted
MRC:
The means of closing the item when inlet pressure decreases.ADSU
Disk Loading Method:
Spring
MRC:
The rated valve discharge capacity per unit of time.ADSY
Valve Discharge Flow Rate:
61500.0 pounds per hour
MRC:
Indicates the type of renewable seating ring in the item.ADZH
Renewable Seat Ring Type:
Threaded
MRC:
The number of bolt holes provided on the item.AECS
Bolt Hole Quantity:
8 1st end
MRC:
The number of bolt holes provided on the item.AECS
Bolt Hole Quantity:
9 2nd end
MRC:
The means used to control the operation of the valve.AQLR
Valve Operation Method:
Automatic or manual
MRC:
The physical configuration of the flange.ARKN
Flange Shape:
Round with holes 1st end
MRC:
The physical configuration of the flange.ARKN
Flange Shape:
Round with holes 2nd end
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
Flange 2nd end
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
Flange 1st end
MRC:
The minimum to maximum pressures at which the item may be set to open.CQCY
Adjustable Pressure Range:
+1380.0/+1460.0 pounds per square inch
MRC:
The predetermined pressure at which the item is calibrated to open.CSDC
Opening Pressure Setting:
1400.0 pounds per square inch
MRC:
The nominal length of a straight line which passes through the center of an item,and terminates at the outside circumference.CWCD
Outside Diameter:
9.250 inches 2nd end
MRC:
The nominal length of a straight line which passes through the center of an item,and terminates at the outside circumference.CWCD
Outside Diameter:
9.625 inches 1st end
MRC:
A nominal measurement of the smallest dimension of an item,in distinction from length or width.CWCK
Thickness:
0.938 inches 3rd end
MRC:
A nominal measurement of the smallest dimension of an item,in distinction from length or width.CWCK
Thickness:
1.063 inches 4th end
MRC:
A nominal measurement of the smallest dimension of an item,in distinction from length or width.CWCK
Thickness:
1.625 inches 1st end
MRC:
A nominal measurement of the smallest dimension of an item,in distinction from length or width.CWCK
Thickness:
1.750 inches 2nd end
MRC:
The nominal length of a straight line which passes through the center of the bolt hole,and terminates at the circumference.CWCQ
Bolt Hole Diameter:
0.812 inches 2nd end
MRC:
The nominal length of a straight line which passes through the center of the bolt hole,and terminates at the circumference.CWCQ
Bolt Hole Diameter:
1.062 inches 1st end
MRC:
The nominal length of a straight line which passes through the center of the bolt circle,and terminates at the circumference.CWCT
Bolt Circle Diameter:
7.500 inches 1st end
MRC:
The nominal length of a straight line which passes through the center of the bolt circle,and terminates at the circumference.CWCT
Bolt Circle Diameter:
7.688 inches 2nd end
MRC:
The design of the flange face.CWDF
Flange Face Design:
Plain 1st end
MRC:
The design of the flange face.CWDF
Flange Face Design:
Plain 2nd end
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Steel body
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Steel stem
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Err-090
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Angle
MRC:
A feature of the item of supply which must be specifically recorded when the reference number covers a range of items.ZZZY
Reference Number Differentiating Characteristics:
As differentiated by the valve discharge flow rate requirement