Part Number
DEMIL
Shelf Life
UOM
NIIN
NSN
National Stock Number:
TXT
Description:
Sensitive Switch
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Hole mounted
MRC:
The specific commercial rating which classes the item as to what degree the item will withstand environmental elements and/or hazardous locations.ABFE
Hazardous Locations/environmental Protection:
Dustproof
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
2.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
2.350 inches
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the actuator.AFUQ
Actuator Style:
Round
Actuator Height:
0.320 inches
Actuator Free Position Height:
1.280 inches
Housing Height:
2.000 inches
MRC:
A measurement of the longest dimension of the housing,in distinction from width.AFWD
Housing Length:
2.060 inches
MRC:
A measurement taken at right angles to the length of a housing,in distinction from thickness.AFWE
Housing Width:
1.340 inches
Center To Center Distance Between Housing Mounting Facilities Parallel To Length:
1.682 inches
Center To Center Distance Between Housing Mounting Facilities Parallel To Width:
1.610 inches
MRC:
The maximum voltage rating at which the item is designed to operate in an alternating current and/or direct current circuit,expressed in volts.AFXE
Maximum Voltage Rating In Volts:
28.0 dc
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Hermetically sealed
MRC:
The means of attaching the item.AXGY
Mounting Method:
Unthreaded hole
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Actuator seal
MRC:
The designation that identifies the electrical configuration of a nonpile-up contact group including the number of switching poles or forms.CRLD
Nonpile-up Contact Arrangement:
2 pole, double throw, one position momentary single switch unit
MRC:
The movement of the switch actuator.CXQQ
Actuator Movement:
Between 185.0 pretravel degrees and 170.0 overtravel degrees and 7.0 differential degrees
MRC:
The amount of current the contacts are rated to make or break at maximum rated voltage,with a specified load.CXQR
Contact Load Current Rating At Maximum Rated Voltage:
25.000 amperes resistive dc
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
6 wire lead