Part Number 61R

Flow Rate Indicating Meter

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
61r
Demil:
No
Shelf Life:
UOM:
NIIN:
010603607

Part Information
Open channel flow recorder, internal matl anodized aluminum

NSN
National Stock Number:
6680-01-060-3607 6680010603607
TXT
Description:
Flow Rate Indicating Meter
INC
INC
Item Name Code:
38346
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
9.375 inches
MRC:
A narrative description of the type of inlet connection.ACQW
Inlet Connection Type:
Any acceptable
MRC:
An indication of whether or not an integral safety device is included.AHZU
Integral Relief Valve:
Not included
MRC:
Indicates the design type of the item.APGF
Design Type:
Case
MRC:
Indicates the type of unit.APQB
Unit Type:
Portable
MRC:
The number of scales on the item.APSJ
Scale Quantity:
1
MRC:
The structural characteristic of the item.ARQS
Construction:
Inclosed w/sight window
MRC:
A narrative description of the type of outlet connection.ARTH
Outlet Connection Type:
Any acceptable
MRC:
The number of floats provided.AWAE
Float Quantity:
1
MRC:
An indication of whether or not a carrying handle is included.AXQG
Carrying Handle:
Not included
MRC:
The minimum and maximum markings on a dial scale.BHBY
Dial Scale Marking Range:
+0.0/+9999999.9
MRC:
An indication of whether or not a base(s) is included.BHJT
Base:
Not included
MRC:
Indicates the type of float used.BHSQ
Float Type:
Free
MRC:
An indication of whether or not an integral heat source is included.BNHN
Integral Heat Source:
Not included
MRC:
An indication of whether or not a dial scale reference pointer is included.CPZK
Dial Scale Reference Pointer:
Not included
MRC:
An indication of whether or not a spinning float is included.CPZM
Spinning Float:
Not included
MRC:
An indication of whether or not an integral pulsation dampener is included.CPZN
Integral Pulsation Dampener:
Not included
MRC:
The inlet connection position for which the item is designed.CPZP
Inlet Connection Position For Which Designed:
Vertical
MRC:
The outlet connection position for which the item is designed.CPZR
Outlet Connection Position For Which Designed:
Vertical
MRC:
An indication of whether or not an alarm signal is included.CPZT
Alarm Signal:
Not included

Similar Flow Rate Indicating Meters