Part Number 62090-1056

Electrical Dummy Load

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
62090-1056
Demil:
Yes - DEMIL/MLI
Shelf Life:
UOM:
NIIN:
014818472

Part Information
F0 to f3 for 2903898-2 inclusive; see requirements 3.3.1 residual noice for 2903898-2; weapon system essential

NSN
National Stock Number:
5985-01-481-8472 5985014818472
TXT
Description:
Electrical Dummy Load
INC
INC
Item Name Code:
00335
INC
COM
Compliance:
MRC:
The ambient temperature of the medium surrounding an item at which it can be operated continuously at full rated power,expressed in degrees celsius.AAQF
Ambient Tempurature In Deg Celsius At Full Rated Power:
1.0 and 65.0
MRC:
The amount of coolant necessary to maintain the required operating temperature of the item.AAXT
Cooling System Coolant Flow Rate:
5.0 gallons per minute
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Missile system, aegis surgace (sms) mk7; arleigh burke class ddg
MRC:
The ratio of the maximum to the minimum amplitude of pressure /voltage/ measured along the path of the waves.AHTW
Voltage Standing Wave Ratio:
1.15
MRC:
The amount of electrical energy that can be dissipated.AJDB
Power Rating:
15.000 kilowatts average
MRC:
Indicates the type of facility provided on the device for attaching to another item.AKRZ
Termination Type:
Waveguide flange
MRC:
The position in which the item is designed to operate.ARNH
Operating Position:
All positions
MRC:
The nominal exerted outward force,per unit of area,for which the item is designed.AWNC
Internal Operating Pressure:
6.0 pounds per square inch gage
MRC:
The nominal outward force,per unit of area,of the coolant chamber.AWNJ
Coolant Chamber Pressure:
15.0 pounds per square inch gage
MRC:
The input temperature of the coolant.AWNL
Input Coolant Temp:
40.0 degrees celsius
MRC:
The means of cooling used to maintain the required operating temperature of the item.BFMF
Cooling Method:
Forced liquid
MRC:
The master requirement codes of those requirements which are technically critical by reason of tolerance,fit,performance,or other characteristics which affect identification of the item.CRTL
Criticality Code Justification:
Feat

Similar Electrical Dummy Loads

« Antennas, Waveguides and Related Equipment Catalog
Compare Now »
Clear | Hide