Part Number
DEMIL
Shelf Life
UOM
NIIN
NSN
National Stock Number:
TXT
Description:
Electromagnetic Relay
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
1.718 inches
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.ABKQ
Center To Center Distance Between Mounting Facilities Parallel To Length:
1.396 inches single mounting facility and 1.446 inches single mounting facility
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.ABKR
Center To Center Distance Between Mounting Facilities Parallel To Width:
0.625 inches single mounting facility
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
1.015 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
1.000 inches
MRC:
A measurement taken at right angles to the length of the mounting slot,in distinction from thickness.ABTD
Mounting Slot Width:
0.150 inches single mounting facility
MRC:
The measure of sensitivity of the item to be packaged. a factor used by packaging engineers in devising proper cushioning in a package.AFJN
Fragility Factor:
Moderately rugged
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Control unit
MRC:
The number of individual /not electrically connected/ windings.AKDX
Winding Quantity:
1
MRC:
The purpose for which the item is designed.AKSL
Purpose For Which Designed:
General
MRC:
The number of coils included on the item.APCN
Coil Quantity:
1
MRC:
The measured opposition to the flow of direct current offered by the item winding.APNA
Winding Dc Resistance Rating:
290.0 ohms single winding
MRC:
Indicates the type of duty provided.APNP
Duty Type:
Continuous
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
4 slotted hole single mounting facility
MRC:
Indicates the type of storage space required for an item in order to provide the degree of protection necessary to maintain serviceability standards.BBRG
Storage Type:
General purpose warehouse
MRC:
The general configuration and relative position of the facilities provided for mounting the item.CQYJ
Mounting Facility Pattern:
Rectangular single mounting facility
MRC:
The designation that identifies the schematic diagram of the electrical configuration of the main nonpile-up contacts including the number of poles or forms.CRNG
Nonpile-up Main Contact Arrangement:
3 pole, single throw, normally open, momentary action
MRC:
The interval for which the item,by design,is purposely delayed between introduction of power into the energizing element and completion of travel of the contact carrier,and/or between interruption of the energizing power and return of the contact carrier to its normal de-energizing position.CRXH
Time Delay:
0.015 seconds fixed operate and release time
MRC:
The designation that identifies the schematic diagram of the electrical configuration of the auxiliary nonpile-up contacts including the number of poles or forms.CSKP
Nonpile-up Auxiliary Contact Arrangement:
1 pole, double throw, two positions momentary
MRC:
The amount and type of voltage required at designated temperature to be applied to the input or energizing element of the item to ensure normal operation of the switching elements.CSXF
Operating Voltage Rating And Type At Specificationified Temp:
29.0 volts dc 25 degrees celsius single winding
MRC:
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.CTDL
Main Contact Load Current Rating At Maximum Rated Voltage:
25.0 amperes ac resistive load and 25.0 amperes dc resistive load
MRC:
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.CTDL
Main Contact Load Current Rating At Maximum Rated Voltage:
5.0 amperes ac lamp load and 5.0 amperes dc lamp load
MRC:
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.CTDL
Main Contact Load Current Rating At Maximum Rated Voltage:
10.0 amperes ac motor load and 10.0 amperes dc motor load
MRC:
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.CTDL
Main Contact Load Current Rating At Maximum Rated Voltage:
15.0 amperes ac inductive load and 12.0 amperes dc inductive load
MRC:
The highest voltage at which the main contacts are rated for normal operation,expressed in volts.CWAB
Main Contact Maximum Voltage Rating In Volts:
200.0 ac and 28.0 dc
MRC:
The amount of current the auxiliary contacts are rated to make or break at maximum rated voltage,with a specified load.CWGM
Auxiliary Contact Load Current Rating At Maximum Rated Voltage:
1.0 amperes ac inductive load and 1.0 amperes dc inductive load
MRC:
The amount of current the auxiliary contacts are rated to make or break at maximum rated voltage,with a specified load.CWGM
Auxiliary Contact Load Current Rating At Maximum Rated Voltage:
2.0 amperes ac resistive load and 2.0 amperes dc resistive load
MRC:
The amount of current the auxiliary contacts are rated to make or break at maximum rated voltage,with a specified load.CWGM
Auxiliary Contact Load Current Rating At Maximum Rated Voltage:
500.0 milliamperes ac lamp load and 500.0 milliamperes dc lamp load
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
11 wire hook all functions